Mitsubishi Electronics 882.00273.00 User Manual

Page of 101
Figure 28: Display Calibration Menu Screen 
 
 
3.  Once in “Scale Calibration”, enter in the scale calibration weight value stamped on 
the side of the weight.  
4.  The controller will prompt you to remove the weight hopper and press OK. 
5.  After touching OK, the controller will display “PLEASE WAIT...” 
6.  Next, the controller will ask you to hang the calibration weight on the right loadcell 
bracket (loadcell A) and press OK. 
7.  The controller will ask you to hang the calibration weight on the left loadcell bracket 
(loadcell B) and press OK. 
8.  Finally, the controller will ask you to replace the weigh hopper in the blender and 
press OK to complete the calibration. 
9.  The controller will verify that the calibration was done correctly by showing 
“Calibration Successful.” 
10.  Press “Done” until you have reached the Recipe screen. 
 
Figure 29: Display Calibration Screen 
 
Enter in the Calibration 
Weight 
Press here to perform 
the calibration 
Current Loadcell 
Bits 
Follow 
Instructions 
Go Back to the 
Calibration Directory 
Verifying Calibration (Recommended on a periodic basis to ensure accuracy) 
1.  From the “Recipe” Page, touch the Manufacturer’s icon and enter “5413”, then press 
the “Enter” key. 
2.  Touch “Calibration” and then “Direct Scale Readout”. 
3.  Remove the weigh hopper. 
4.  Locate the weight display for each of the two load cells directly below “Current 
Bits.”  Write down the displayed value. 
BF1-615.3 
Chapter 3: 2BInstallation 
40 of 101