Troubleshooting (cont.)
Brewing Problems
Problem
Possible Causes
Service Check
Remedy
Brew cycle will
not start
• Controller faulty.
• Check to see that the
power is supplied to the
controller by following
instructions given in 
the Troubleshooting
section 
on Filling
Problems. 
Once 
touchpad and momentary
switch integrity is 
assured (see above), 
initiate a brew cycle 
and check for 24 Vac
across brew valve.
• If there is not 24 Vac across
brew valve, replace control
board.
Sprayhead will not
stop dripping water
• Brew valve not closing
completely.
• Water in tank boiling.
• Visually inspect brew
valve at hose 
connections.
• Remove sprayhead 
and determine if drip is
coming from overflow.
• Clean lime from valve. Seat,
cup or entire valve may need
replacement.
• Reduce tank temperature.