Shuttle Brewers & Airpot/Shuttle Brewers
Adjustments (cont.)
Brew Volume “br”
Brew time can be set for each size visually. See Setting Brew Volume Procedure below.
Brew time can also be adjusted through the display. See Programming Routine section.
Setting Brew Volume Visually
1. Remove brew basket and place container under brew head.
2. Press and hold desired brew button for 5 seconds. Display will read “Pro”.
3. Within 20 seconds, press and release desired brew button. Water will dispense from spray head and time
will count-up in display.
4. When volume is at desired amount, press and release brew button to stop flow. Time will flash in display.
5. Within 20 seconds, press and release desired brew button. Display will clear and brew time will be stored
into memory.
Note: During this routine, no pulsing or bypass will occur.
Note: If the On/Off button is pressed during procedure, time setting will default to previous time.
Control Features
Pre-infusion: Controls the initial coffee grounds wetting and the first dwell time after the initial wetting. Pulse brews
are the series of pulses after the Pre-infusion process. All pulse ON and OFF times are the same.
Brew Countdown Timer: After the start of a brew the LED display will countdown the remaining time left in the brew
process. The countdown will include all OFF periods programmed in the Pre-infusion and the pulses. At the end of
the brew time, the display will scroll driP, while the brew basket drains itself. At the end of the drip cycle, the display
will scroll doneE for 30 seconds then turn off.
Energy Savings Mode: If enabled, when the brewer is idle for three (3) hours this feature will allow the water tank to
lower its holding temperature to 120°F. The display will scroll SLEEPIng while in this mode.
Copy-to-Left: On twin brewers, this feature allows you to copy the brew parameters programmed on a particular
brew portion on the Right side to the Left side. 
Programming
On twin brewers, the right side, Large portion button gives the user access to the global programming parameters of
the brewer, such as; Tank Temperature, Energy Savings Mode, Enable/Disable Low Temp No Brew, ON/OFF, Drip
Time and Bypass Ratio. After the global parameters are set, the individual portion brew parameters can be set. All
other portion sizes (left and right) only access individual brew parameters to that particular portion. Also, on twin
brewers, the last program step in programming individual brew parameters allows the operator to copy those brew
parameters to the left side if “YES” is selected. If “YES” is selected, the brew parameters that were set for the right
side for that particular portion are copied to the left side. If “NO” is selected, then the left side must be programmed
separately.
To enter program mode:
Press the UP and DOWN arrows simultaneously for 5 seconds. Once in program mode, the green LED for each por-
tions size will flash.