Bunn SNG0033000 User Manual

Page of 38
Page 38
SERVICE TOOLS (cont.)
3.  Press and hold the upper right hidden switch until 
the display reads UNITS.  Release the switch. 
Continue pressing and releasing the upper right 
hidden switch until SERVICE TOOLS appears. 
4. Pressing NO  will exit this function and advance to 
the next function screen. Press YES to run tests 
on various components and outputs within the 
brewer.
5.  The display should read TEST OUTPUTS?.
6. In TEST OUTPUTS screen, press NO.  Continue 
to press and release NO until the display reads  
TEST FREQUENCY?.
7.  Press and release YES. The display will show the 
frequency of the sensor coil circuits. This is for 
diagnostic service use when troubleshooting this 
circuit.
8.  After the coils have been tested, press and release 
the ON/OFF switch (either on DUAL brewers) 
located on the front switch panel. This will exit 
the TEST FREQUENCY function and return to the 
MAIN SCREEN.
NOTE: If the operator wishes to test more than one 
function in the SERVICE TOOLS section (outputs, 
switches, servers, or coil frequency), it is not 
necessary to exit the program. Use the flow chart 
for SERVICE TOOLS to navigate to a particular 
function.
PROGRAMMING THE BREWER (cont.)
FACTORY DEFAULTS
 
This function allows the operator to erase all of the 
previously entered recipes and ad messages. Factory-
set default values will replace all previous settings.
Procedure to set factory defaults:
1.  Press and hold the upper right hidden switch until 
UNITS  appears. Release the switch. Press and 
release the upper right hidden switch until the 
display reads SEL BREWER TYPE?
2. Pressing 
NO in this screen will advance to FACTORY 
DEFAULTS. Press and release YES. The display 
should read ThermoF SoftHeat. The selected 
brewer type will be flashing. When correct brewer 
type is selected press DONE.
3.  The display should now read FACTORY DEFAULTS
Pressing NO in this screen will revert to the MAIN 
SCREEN.  Press YES to replace the defaults.  This 
advances to WILL REPLACE ALL BREWING SET-
EXIT
EXIT
REPLACE
WILL REPLACE ALL
BREW SETTINGS
ARE YOU SURE?
NO                     YES
FACTORY DEFAULTS
NO                     YES
ThermoF  SoftHeat
DONE
SEL BREWER TYPE?
NO                     YES
P2312
TINGS. This screen will alternate with ARE YOU 
SURE?.
4. Pressing NO in the confirmation screen will revert 
to MAIN SCREEN, without resetting the brewing 
setups to the defaults. Press YES to load the de-
faults. This will then revert to the MAIN SCREEN
and the factory default values will replace all 
previously entered values. It will NOT reset the 
summation Brew counter.
41341 080108