Bunn S/N DUAL068000 User Manual

Page of 54
Page 11
MAIN SCREEN
 
This screen will be shown when the brewer is ready 
for use. The screen displays the water temperature 
in the tank. When the water in the tank reaches the 
correct set temperature, the display will change from 
HEATING to READY TO BREW.
PROGRAMMING  LOCKOUT  SWITCH  (mounted  on 
main control board)
 
This switch can be set to prevent access to the 
programming levels of the brewer. Once all the cor-
rect brew settings are programmed, the operator can 
set the switch to the "DISABLE" position to prohibit 
anyone from changing the settings.
BREW LOCKOUT
 
This  function  allows  the  operator  to  prevent  or 
allow brewing if the water temperature is less than 
the set READY temperature.
 
To access this function screen press and hold the 
® symbol. Release the ® when the display reads:
Press here 
for NO
Press here 
for DONE
Press here 
for YES
PROGRAM FUNCTIONS - LEVEL 1
 
The YES or NO should be flashing. Select YES to 
prevent brewing if the water temperature is below the 
set READY temperature. Select NO to permit brewing 
at any water temperature.
 
When  finished,  press  and  release  DONE.  This 
will exit this function screen and return to the MAIN 
SCREEN on the display.
PROGRAMMING THE BREWER
 
The programming of the brewer is divided into two levels. There is one function in Level 1. All other functions 
are accessed in Level 2.
 
 The following function screens are in order of appearance. Each screen will have instructions on how to 
access, and the procedures to program the various functions of the brewer.
IMPORTANT PROGRAMMING NOTES
- READ CAREFULLY - 
 
To exit the programming mode at any time, press and release either ON/OFF switch located on the front switch 
panel. The display will return to the MAIN SCREEN.
 
If none of the five programming switches are pressed within one minute during the setup of the brewer, 
the programming of the function screen that is being set will be exited and the display will return to the MAIN 
SCREEN.
 
Always remember to place a container and funnel under the sprayhead when operating the brewer during the 
set-up of PULSE BREW, CALIBRATE FLOW and testing the brew and bypass valves in SERVICE TOOLS/TEST 
OUTPUTS.
PROGRAM
ENABLE
DISABLE
PROGRAMMING 
SWITCH
P2424
BREW  LOCKOUT?
 NO 
DONE 
YES
29877-3 062005
READY TO BREW
WATER TEMP: 200°