Procedure to set funnel detect:
1.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch. Continue 
to  press  and  release  switch  until  display  reads 
FUNNEL DETECT.
2.  NO or YES should be flashing to indicate the cur-
rent setting.
4.  Select YES to prevent brewing if a Smart Funnel is 
not correctly situated in the rails.  If this function 
is activated and a brew cycle is attempted with the 
funnel not properly situated, the display will read,  
FUNNEL NOT IN PLACE, until one is in place.
5.  Select NO to allow brewing without a Smart Fun-
nel in place. This is selected when brewing with a 
funnel other than a Smart Funnel (a regular brew 
funnel).
6.  When finished, press and release DONE. This will 
retain the changes, exit this function screen and 
advance to the next. Another alternative is to press 
either ON/OFF switch located on the front switch 
panel to exit the FUNNEL DETECT and return to 
the MAIN SCREEN.
P2721
5.  When finished, press NEXT to advance counter 
screens  until  the  display  reads  BREW  COUN-
TERS. Press and release NO to advance to the 
next function screen, or press  and release either 
ON/OFF switch on the front switch panel to exit 
the BREW COUNTERS function and return to the 
MAIN SCREEN.  
FUNNEL DETECT (optional)
 
This function allows the operator to prevent the 
start of a brew cycle if a Smart Funnel is not positioned 
correctly in the funnel rails.
P2721
Procedures to set server detect:
1.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch.  Continue 
to  press  and  release  switch  until  display  reads 
SERVER DETECT.
2.  The  NO  or  YES  flashes  to  indicate  the  current 
selection.
3.  Select  YES  to  prevent  brewing  if  the  Soft  Heat 
server is not correctly positioned on the brewer 
beneath the funnel.  
NOTE: If  YES is selected and a brew cycle is attempted 
with a server not properly placed, the display will read 
SERVER NOT IN PLACE.
4.  Select NO to allow brewing without a Soft Heat 
server in place. This is selected when brewing into 
a container other than a Soft Heat Server.
5.  When finished, press and release DONE. This will 
save the new setting, exit the function screen and 
advance to SERVICE TOOLS. Another alternative is 
to press either ON/OFF switch located on the front 
switch panel to exit the SERVER DETECT function 
and return to the MAIN SCREEN.
SERVER DETECT
 
This function allows the operator to prevent the start 
of a brew cycle if a Soft Heat server is not positioned 
correctly on the brewer.
BREW COUNTERS (cont.)
FUNNEL DETECT ?
  NO 
DONE 
YES
SEVER DETECT ?
  NO 
DONE 
YES
PROGRAMMING THE BREWER (cont.)
29877-3 062005