Bunn S User Manual

Page of 44
Page 24
J2
SE
T  
   L
OC
K
L
O
C
K
S
E
T
TL1
TL2
TL3
TL4
TL5
J1
SERVICE (cont.)
DIGITAL BREW TIMER (Late Models)
P2181
FIG. 16 DIGITAL BREW TIMER
29251 011501
Location:
The  timer  is  located  inside  the  front  inspection
panel. Some earlier models, with the new timer will
have them located inside the rear panel.
Test Procedures:
NOTE: Do not remove or install wires while timer board
is installed. Pressure applied to one side may cause
damage to the board.
1. Disconnect the brewer from the power source  and
remove the front panel.
2. With a voltmeter, check the voltage across termi-
nals TL1 and TL2 when the "ON/OFF" switch is in
the "ON" position. Connect the brewer to the power
source. The indication must be:
a.) 120  volts  ac  for  two  wire  120  volt  models,
three  wire  120/208  volt  models  and  three  wire
120/240 volt models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
3. Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If  voltage  is  not  present  as  described,  refer  to  the
Wiring  Diagrams  and  check  the  brewer  wiring  har-
ness.
4. With a voltmeter, check the voltage across termi-
nals TL1 and TL4 when the "ON/OFF" switch is in
the "ON" position. Connect the brewer to the power
source. The indication must be zero volts.
If voltage is as described, proceed to #5.
If voltage is not as described, disconnect the brewer
from the power source and replace the timer.
5. With a voltmeter, check the voltage across termi-
nals TL1 and TL4 when the "ON/OFF" switch is in
the "ON" position. Connect the brewer to the power
source and press the start switch. The indication
must be:
a.) 120  volts  ac  for  two  wire  120  volt  models,
three  wire  120/208  volt  models  and  three  wire
120/240 volt models.
b.) 200 to 240 volts ac for two wire 200 or 240 volt
models.
If voltage is as described, the brew timer is operating
properly. Reset the timer as required, to obtain the
desired brew volume.
If voltage is not as described, test the START switch for
operation before replacing the timer (see page 19).
Test ON/OFF Switch if START Switch is functional (see
page 17).  If voltage is as described for both switches,
disconnect  the  brewer  from  the  power  source  and
replace the timer.
Removal and Replacement:
NOTE: Do not remove or install wires while timer board
is installed. Pressure applied to one side may cause
damage to the board.
1. Remove  the  two  #6-32  screws  securing  circuit
board to component mounting bracket.
2. Remove circuit board and nylon spacers.
3. Remove all wires from the timer.
4. Attach  all  wires  to  the  replacement  timer  board
prior to installation to the component mounting
bracket. Refer to FIG. 17  when reconnecting the
wires.
5. Install  new  circuit  board  with  nylon  spacers  to
component mounting bracket.
6. Adjust the timer as described below.