SERVICE (cont.)
THERMAL CUT-OFF (Models SA, STA & STFA)
Location:
The    thermal  cutoffs  are  located  on  both  tank
heater terminals.
Test Procedures:
1.
Disconnect the brewer from the power source.
2.
Disconnect  the  thermal  cutoff  from  the  tank
heater terminal and the limit thermostat or wir-
ing harness.
3.
Check for continuity across the thermal cutoff
terminals using an ohmmeter.
If continuity is present, the thermal cutoff is operating
properly.  If  continuity  is  not  present  as  described,
replace the thermal fuse.
Removal and Replacement:
1.
Disconnect  the  thermal  cutoff  from  the  tank
heater terminal and the limit thermostat or wir-
ing harness.
2.
Remove thermal cutoff and discard.
3.
Connect new thermal cutoff to the tank heater
terminal and the limit thermostat or wiring har-
ness.
4.
Refer to FIG. 24 when reconnecting wires.
FIG. 24 THERMAL CUT-OFF
P1593
Thermal cutoff to BLK Lead
Thermal cutoff to WHI or RED Lead
29251 052500