release DONE to advance to next function screen, 
CALIBRATE FLOW. Another alternative is to press 
and release either ON/OFF switch located on the 
front switch panel to exit the BYPASS OZ/M func-
tion and return to the MAIN SCREEN.
CALIBRATE FLOW
 
This function allows the operator to enter the actual 
fl ow rate of the sprayhead and the bypass for each 
side of the brewer by dispensing both separately for 
one minute. The volumes are then entered in ounces 
per minute (OZ/M). 
Procedures to calibrate the sprayhead fl ow rate:
1.  Place a container, accurately graduated in ounces, 
and with a minimum capacity of 60 ounces, be-
neath the funnel on the side of the brewer to be 
calibrated.
2.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch. Continue 
to press and release switch until display reads 
CALIBRATE FLOW ?.
3.  Press and release YES to advance to the SPRAY 
HEAD CAL? function screen. (Pressing NO in the 
CALIBRATE FLOW screen will advance to the next 
function screen, BREW COUNTERS).
4. Press and release YES. The display should read 
CONTAINER READY? If the container is under 
the funnel, press YES.  The display should read 
CALIBRATE SPRAY .. PRESS BREW TO START.
5.  Press and release the BREW switch on the side to 
be calibrated. The display should read CALIBRATE 
SPRAY .. 60 SEC TO FINISH.
 The 60 second timer 
on the display will count down to zero. When the 
counter reaches zero, the display will change to 
ENTER  OZ,  along with a number signifying ounces 
per minute.
6.  Measure the amount of water in the container 
and using the (-) or (+), adjust the amount on the 
display to match the amount in the container. Then 
press DONE.
7.  The display should now read NEW L or R SPRY 
FLOW, along with the correct fl ow rate of the 
sprayhead in ounces per minute. After about 5 
seconds, the display will return to the CALIBRATE 
FLOW 
screen.
8.  To exit the CALIBRATE FLOW program, press NO 
to advance to the next function screen, or press 
PROGRAMMING THE BREWER (cont.)
Procedure to adjust the fl ow rate setting:
1.  Press and hold upper right hidden switch until the 
display reads UNITS. Release switch.  Continue to 
press and release switch until the display reads 
L SPRY OZ/M. The number represents what the 
brewer thinks is the fl ow rate of the sprayhead in 
ounces per minute.
2.  If the actual fl ow rate of the sprayhead is known, 
but is different than the number on the display, 
use the (-) and (+) to enter the correct fl ow rate 
in ounces per minute.
3. When 
fi nished, press and release DONE.  This saves 
the new setting and advances to R SPRY OZ/M. 
When fi nished setting the right side, press and 
release DONE to advance to next function screen, 
L BYPS OZ/M. Another alternative is to press and 
release either ON/OFF switch located on the front 
switch panel to exit R SPRY OZ/M function and 
return to the MAIN SCREEN.
BYPASS OZ/M
 
This function allows the operator to view or to enter 
the actual fl ow rate coming out of the bypass nozzle.  
This is NOT used to change the actual fl ow rate, but to 
tell the internal controller how fast the water is fl owing. 
The unit of measure is ounces per minute.
P2721
L BYPS OZ/M: XXX
 (-)  DONE  (+)
Procedure to adjust the fl ow rate setting:
1.  Press and hold upper right hidden switch until 
display reads UNITS. Release switch. Continue 
to press and release switch until display reads 
BYPASS OZ/M
. The number represents what the 
brewer thinks is the fl ow rate of the bypass valve 
in ounces per minute.
2.  If the actual fl ow rate of the bypass valve is known, 
but is different than the number on the display, 
use the (-) and (+) to enter the correct fl ow rate 
in ounces per minute.
3.  When fi nished,  press and release the DONE.   This 
saves the new setting and advances to R BYPS 
OZ/M
. When fi nished setting right side, press and 
35058.1 071205