FIG. 4 AUGER MOTOR CAPACITOR TERMINALS
SERVICE (CONT.)
AUGER MOTOR CAPACITOR
FIG. 3 AUGER MOTOR CAPACITORS
P1341
Location:
The auger motor capacitors are located on the lower 
right side of the auger motor mounting bracket inside 
the auger motor covers.
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect  the  wires  from  the  capacitor  to  be 
tested.
3  With  a  voltmeter,  check  for  voltage  across  the 
white/blue wire on the right capacitor, the white 
/brown wire on the left capacitor, or the grey wire 
on the center capacitor and the white/black wire 
on the auger motor terminal. Place the appropriate 
auger switch in the “-” (“ON”) position. Connect the 
dispenser to the power source.The indication must 
be:
 
a) 120 volts ac for 120 volt models.
 
b) 230 volts ac for 230 volt models.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the Wiring 
Diagram and the dispenser wiring harness.
5.  Check for continuity across the auger motor capaci-
tor terminals.
If  continuity  is  present  as  described,  reconnect  the 
wires to the auger motor capacitor.
If continuity is not present as described, replace the 
auger motor capacitor.
P1324
Removal and Replacement
1.  Remove the two #8 locking screws securing the 
auger  motor  cover  to  the  cooling  drum  mount 
assy.
2.  Remove the cover and set aside for reassembly.
3.  Disconnect the wires from the auger motor capaci-
tor terminals.
4.  Remove the #8 locking screw on the lower right 
side of the auger motor mounting bracket securing 
the auger motor capacitor.
5.  Install a new capacitor on the lower right side of 
the auger mounting bracket and secure with a #8 
locking screw.
6.  Reconnect the wires to the capacitor terminals.
7.   Refer to Fig. 4 when reconnecting the wires.
27646 022500