Removal and Replacement:
1.  Disconnect the lamp cord assembly from the lamp 
cord connector assembly in the top of the auger 
motor cover.
2.  Remove the hopper cover with the lamp cord as-
sembly from the hopper.
3.  Remove  hopper  cover  liner  from  the  hopper 
cover.
4.  Cut off the closed-end splices connecting lamp cord 
assembly to the lamp holder/socket assembly.
5.  Remove the two lamps.
6.  Remove  the  two  #2-56  screws  and  elastic  lock 
nuts securing the lamp holder/socket assembly to  
the mounting bracket. Remove lamp holder/socket 
assembly and discard.
7.  Install new lamp holder/socket assembly on mount-
ing bracket using two #2-56 screws and elastic lock 
nuts.
8.  Reinstall lamps.
9.  Strip the wires from the lamp cord assembly ap-
proximately .375”.
10. Using  the  two  wire  nuts,  supplied,  connect  the 
lamp cord assembly to the new lamp holder/socket 
assembly wires.
11. Reinstall the hopper liner to the bottom of the hop-
per cover.
12. Reinstall the hopper cover to the hopper.
13. Plug in the lamp cord assembly to the lamp cord 
connector assembly on left top of the auger motor 
cover.
14. Refer to Fig. 42 when reconnecting the wires.
FIG. 42 LAMP HOLDER/SOCKET ASSEMBLY
WIRES
P1322
SERVICE (cont.)
LAMP HOLDER/SOCKET ASSEMBLY
FIG. 41 LAMP HOLDER/SOCKET ASSEMBLY
P1343
Location:
The  lamp  holder/socket  assemblies  are  located 
inside the hopper covers.
Test Procedures:
1.  Disconnect the lamp cord assembly from the lamp 
cord connector.
2.  Remove  the  lamps  from  the  lamp  holder/socket 
assembly.
3.  With a voltmeter, check the voltage across the pin 
sockets in the plugs with the DAY/NIGHT switch in 
the “-” down position and ON/OFF switch in the “ON” 
position. Reconnect the lamp cord to the lamp cord 
connector. The indication must be approximately 
12.6 volts dc.
4.  Disconnect the lamp cord from the lamp cord con-
nector.
If  voltage  is  present  as  described,  the  lamp  holder/
socket assembly is operating properly.
If voltage is not present as described, replace the lamp 
holder/socket assembly.
5.   Check for continuity across the terminals on the 
lamps.
If  continuity  is  present  as  described,  the  lamps  are 
operating properly.
If continuity is not present as described, replace the 
lamp.