OmniTek XR User Manual

Page of 78
 
 
 
 
 
Page 
75
Setting up the OmniTek System 
 
This section explains how to set up the OmniTek system to perform the delay testing operations. 
Gen Setup 
If Gen is to be used for generating the special A/V Delay Test Sequence, this is the sequence of 
operations required: 
1.  Set the Gen system to the correct video format in the “Engineering > Video Setup > General” 
menu. 
2.  Make sure no other images are loaded into the Gen desktop. 
3.  Load the 192 frames of the special A/V Delay Test Sequence that is applicable to the current 
video format. Choose the “no fit” option if necessary. Then play the sequence in an endless loop, 
by using the icons on the transport toolbar. 
 
 
 
 
4.  In the menu “Engineering > Audio Setup”, make sure that the audio tone on channel 1 is set for 
8kHz, -18dB, and present only on frame 1 of the sequence.  This setting is essential for correct 
operation.