Market Forge Industries 30-stel-lx User Manual

Page of 30
SECTION 2 INSTALLATION INSTRUCTIONS
TABLES 2.1 AMPS PER LINE PER LINE WIRE
MODELS: 30-STEL, 30-STEL-LX, 30-STEM & 30-STEM-LX
3 pH, 4 Wire, 50Hz Amps Per Line Wire
12kW, 1 pH, 60Hz Amps Per Line Wire
10.1kW
12kW
15
16.7
220/380V
240/415V
(EXPORT ONLY)
208V
240V
L #2
52
50
L #1
52
50
12kW, 3 pH, 60Hz Amps Per Line Wire
208V
240V
480V
L #3
33
29
14.5
L #2
33
29
14.5
L #1
33
29
14.5
MODELS: 40-STEL, 40-STEL-LX, 40-STEM & 40-STEM-LX
3 pH, 4 Wire, 50Hz Amps Per Line Wire
18kW, 1 pH, 60Hz Amps Per Line Wire
15.1kW
18kW
23
25
220/380V
240/415V
(EXPORT ONLY)
208V
240V
L #2
87
75
L #1
87
75
18kW, 3 pH, 60Hz Amps Per Line Wire
208V
240V
480V
L #3
50
43
22
L #2
50
43
22
L #1
50
43
22
1. Remove carton from skid, being careful not to dent or 
scratch finished surfaces of unit.
2. Inspect unit carefully for shipping damage. File claim with 
carrier immediately if damage is found.
3. Remove screws holding unit to skid.
4. Transfer unit to desired position. Make unit level and 
steady by adjusting feet to compensate for floor 
irregularities. Secure rear feet to floor by using 5/16" 
screws.
NOTE: Do not install in such a manner that service person 
cannot remove control box cover.
5. Drop down hinged front cover of connection box. Loosen 
screws and clips on top of box.
6. Connect unit to a branch circuit having a voltage and 
circuit type specified on name plate and of sufficient size 
to carry load. The amps per line per line wire for the 
various voltage ratings are shown in Table 2.1 below.
NOTE:  Supply  wires  must  be  suitable  for  temperature  of  at 
least 90°C.  Additionally,  all  wiring  must  conform  to  the 
requirements  of  local  and  national  electric  codes.  Conduit 
and fittings should be watertight type.
7. Connect ground wire from electrical service to ground lug.
 
8. Reinstall hinged front cover of connection box securely.
9. Ensure that skillet is firmly seated on frame before 
checking connection and functioning of controls.
NOTE:  Unit  is  equipped  with  an  interlock  switch  that  shuts 
off  current  to  heating  elements  when  skillet  pan  is  more 
than 10° above normal horizontal cooking position.
10. Switch on current supply to unit. Check for proper 
functioning of controls and heating elements (see 
Section 3—Operating Instructions).
2-1