CHAPTER 1:  INSTALLATION INSTRUCTIONS
 
 
 
1-2
 
For units equipped with legs:  Lift the unit and move it into its final position.  Do not drag or push the fryer into position. 
Doing so may damage the legs.  Level the unit front to back and side to side. If the fryer is not level, the unit will not 
function efficiently.  Super Runner Series gas fryers cannot be curb mounted and must be equipped with either legs or 
casters provided. 
 
A.  Adjust leg height with an adjustable or 1-1/16-inch (27-mm) open-end wrench by turning the hexagon-shaped foot 
on the bottom of the leg.  NOTE:  The foot is for minor leg height adjustment only.  Do not adjust outward more 
than ¾-inch (19-mm)
 
B.  When leveling the unit, the leg body should be held firmly to keep the leg from bending or rotating while turning the 
foot to the required height. 
 
For units equipped with casters:  Roll the unit into its final position and lock the front casters.  
 
 
1.3  Pre-Connection Preparation
 
 
 WARNING 
If the incoming gas pressure is in excess of ½" PSI (3.45 kPa/35 mbar), a step-down regulator will be 
required. 
 
CE UNITS ONLY: 
 
Dean Super Runner gas fryers have obtained CE markings for countries and gas categories shown below: 
 
Countries 
Supply Pressures and Gas (mbar) 
Appliance Categories 
G20  
20/25 
BE Belgium 
G31       
37 
IIE(R)B3P 
G20 
20 
I2E   
DE Germany 
G31 50  I3P 
DK Denmark  G20 
20 
I2H 
G20 20 
ES Spain 
G31 
37 and 50 
II2H3P 
G20/G25 20/25 
FR France 
G31 
37 and 50 
II2ESI3P 
G20 20 
GB Great 
Britain 
G31 37 
II2H3P 
G20 20 
GR Greece 
G31 
37 and 50 
II2H3P 
G20 20 
IR Ireland 
G31 37 
II2H3P 
IT Italy 
G20 
20 
I2H 
G20/G25 20/25 
LU Luxembourg 
G31 50 
II2E3P 
G25 25 
NL The 
Netherlands 
G31 50 
II2L3P 
G20 20 
PT Portugal 
G31 37 
II2H3P 
 
 
NON-CE UNITS ONLY:  
 
NATIONAL CODE REQUIREMENTS: 
 
This equipment is to be installed in compliance with the Basic Plumbing Code of the Building Officials and Code 
Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food and Drug 
Administration. 
 
This equipment is manufactured to use the type of gas specified on the rating plate attached to the door. Connect 
equipment stamped "NAT" only to natural gas and that stamped "PRO" only to LP (Propane) gas.