Haier DW-40L508 User Manual

Page of 12
Display
Display
Display
Display and
and
and
and alarm
alarm
alarm
alarm
Upon connecting to the power supply, the freezer will be on and the display screen
will show the freezer’s internal temperature.
Prompts for the working state of display panel:
“Lock” indicator: if the indicator lights up, it means that all keys are locked to
avoid misoperation.
“Alarm” indicator: if the indicator lights up or flashes, it means that a fault occurs.
Functions of keys:
Cancel buzz: in the locked or unlocked state, press the “Cancel buzz” key at the
time of alarm, the alarm sound will be cancelled and the visual alarm will not be
cancelled.
Alarm test: it is used to test normal working state of the alarm system and low
battery charge level. In the unlocked state, press this key, all the indicators will light
up, the buzzer will give an alarm and all digital tubes display “8”. In the locked state,
press this key at the time of alarm, corresponding fault alarm code will display.
Please identify the fault causes according to the table below.
Alarm
State
Fault
code
Indication
Buzzer
High
temperature
alarm
When
the
internal
temperature
is
higher
than the set temperature
for
high
temperature
alarm
E9
The
indicator
flashes
When
the
freezer
is
turned on for the first
time, the buzzer alarm
function
is
activated
after 5 hours according
to the default settings; in
normal
operation,
the
buzz alarm is given after
15min
Low
temperature
alarm
When
the
internal
temperature
is
lower
than the set temperature
for
low
temperature
alarm
E10
The
indicator
flashes
Power-dow
n alarm
Power-down
of
the
freezer
/
The
alarm
indicator
flashes;
black
screen
and
actual
internal
temperature
show alternately
the buzz alarm is given
after 30s
Over-high
ambient
temperature
Ambient
temperature
above 38℃
E14
The
indicator
flashes
Abnormal
sensor
Internal main sensor at
fault
E6
The
indicator
flashes
Buzz alarm
Ambient
temperature
sensor at fault
E0
The
indicator
flashes
Low
battery
charge
level
Insufficient
battery
charge or the battery
switch is not on
E5
The
indicator
flashes 3 times
Note: If several alarms sound simultaneously, each fault code displays 3s.
Display
Display
Display
Display and
and
and
and alarm
alarm
alarm
alarm
Note:
Always turn on the battery switch before starting the freezer. The freezer will enter
normal working state and charge the battery upon connecting to an AC power supply
meeting its requirements. In case of AC power failure, the battery will energize the
display screen for normal display. When the voltage of battery reduces to less than a
specified value due to discharge, it will stop energizing the display screen and thus
the display screen will not display any longer. When the battery is able to supply
electricity normally, to completely cut off the freezer’s power supply, just pull out its
AC power cord and turn off its battery switch. Then the display screen will not
display any longer.
Time
Time
Time
Time setting
setting
setting
setting for
for
for
for automatic
automatic
automatic
automatic alarm
alarm
alarm
alarm recovery
recovery
recovery
recovery
At the time of alarm, press the “Cancel buzz” key on the display panel, buzz alarm
will be cancelled (remote alarm will not be cancelled).
If alarm conditions remain, the buzz alarm will automatically recover after a pause of
30min.
Remote
Remote
Remote
Remote alarm
alarm
alarm
alarm terminals
terminals
terminals
terminals
The remote alarm terminals are located in the compressor compartment at the back of
freezer. Alarm signals are sent by these terminals with carrying capacity of DC 30V, 2A.
Contact output:
In normal conditions, both ends of connecting wire of remote alarm terminals are
open circuit. In alarm conditions, both ends of connecting wire of remote alarm
terminals are closed circuit.
To use the remote alarm function, connect the circuit as shown in the figure below.
Note: The remote alarm function is limited to three alarm modes - high temperature
alarm, low temperature alarm and power-down alarm.