Taylor 345/346/349/355 User Manual

Page of 87
355/355a/356
052840-58
11/12/13
YEL
BLK
YEL
BLK
RED/WHT
WHT
PRP/WHT
WHT
BLU/WHT
WHT
ORN
ORG/WHT 
BRN
RED/BLK 
BLK
LED
BARREL 2
LED
BARREL 1
RED/BLK
BLK
BLK
RED/BLK 
BARREL 2
BARREL 1
BLK
BLK
BRN
RED
BLK
BLK
BLK
RED
BARREL
2
BIB
SWITCH
BARREL
2
HOPPER
FILL
SWITCH
THERMISTORS
PROBES
RIBBON CABLE     SEE NOTE 2
WHT/BLK 
BLK
LCD DISPLAY
RIBBON CABLE
SEE NOTE 2
RIBBON CABLE
SEE NOTE 2
RIBBON CABLE
SEE NOTE 2
WHT
PROXIMITY
SWITCHES
BARREL 2
BARREL 1
RIBBON CABLE     SEE NOTE 2
RIBBON CABLE     SEE NOTE 2
BARREL 1
KEYPAD
BARREL 2
KEYPAD
NOTE:
      1. STATIC ELECTRICITY MAY CAUSE
         DAMAGE TO SOLID STATE COMPONENTS.
         ELIMINATE STATIC ELECTRICITY BY TOUCHING
         GROUNDED UNIT BEFORE HANDLING SOLID STATE
         COMPONENTS.
      2. STRIPED WIRE ON RIBBON CABLES
         MUST BE CONNECTED TO PIN 1
         AT EACH END.
BRN
BRN
BRN
BRN
BARREL 2
SYRUP OUT
SWITCH
L1
L2
L2
L1
LINE
LOAD
M
BLK
W2
BLK
BRN
ORG/WHT
ORN
PRP/WH
ORN/WHT 
BRN
WHT
ORN
ORN
BLK
BLK
WHT/BLK 
3
2
1
4
H2O
PRESSURE
SWITCH
PRP/WHT 
PRP/WHT 
BRN
RED
BLK/YEL 
BRN
YEL
BLK
YEL
BLK
M
FAN
WHT
BLK
BLK
BLK
WHT
BRN
PRP
PRP
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
WHT
BLK
BLK
RED
BLK
C02
PRESSURE
SWITCH
BARREL
1
HOPPER
FILL
SWITCH
BARREL
1
BIB
SWITCH
BARREL 1
SYRUP OUT
SWITCH
HPCO
L1
BLK
BLK
WHT/BLK 
BLK
WHT
YEL
WHT
WHT
BLK
BLK
BLK
RED
BLK
BLK
WHT/BLK
3
6
1
BEATER MOTOR WIRING
YEL
WHT
WHT/BLK
BLK/WHT 
BLK/WHT
M
WHT
BLK
CARBONATOR FILL SWITCH
WHT
BLK/WHT 
WHT
WHT
WHT/BLK 
WHT
C
NO
C
NO
BRN
BLK
BLU
BRN
BLK
BLU
BRN
BLU
RED
RED
BLU
15A FUSE
GROUND FRAME
SECURELY
BARREL
2
DEFROST
SOLENOID
RED/WHT 
WHT
BLK
BLK
BARREL 1
SAMPLER SWITCH
(PUSHBUTTON-OPTIONAL)
BLK
BLK
BARREL 2
SAMPLER SWITCH
(PUSHBUTTON-OPTIONAL)
P.O.P.
DISPLAY
WHT
L2
RED
3
2
RED/BLK
FAN MOTOR
RUN CAPACITOR
USED WITH AIR
COOLED UNITS ONLY
BLK
BLK/WHT
6
1
(SEE FIG.1 IF REMOTE CARBONATOR)
OPTIONAL
CONTROL SWITCH
SPST
N
L3
GRN
GRN/YEL
GRN/YEL
GRN/YEL
OPTIONAL
OPTIONAL
COMPRESSOR
CONTACTOR
L3
T3
BLK
BLK
GRN/YEL
BLK
GRN/YEL
GR
N/YEL
WHT
WHT
LEESON
2
4
1
YEL
WHT
WHT/BLK 
COMPRESSOR
T2
L1
L2
COMPRESSOR
CONTACTOR
COMPRESSOR
CONTACTOR
T1
CARBONATOR
PUMP
CCW ROTATION
FROM LEAD END
M
BLK
CARBONATOR
FILL SWITCH
WHT
BLK/WHT
L1
2
1
BLK
3
WHT
BLK
BLK
BLK
WHT
GRN/YEL
BLK
WHT
GRN/YEL
N
LOW H2O PRESSURE
INDICATOR LIGHT
H2O 
PRESSURE
SWITCH
REMOTE CARBONATOR WIRING
GRN/YEL
FIG. 1
GRN/YEL
CONTROL
ENCLOSURE(S)
1
2
12
11
PRIMARY
SECONDARY
BEATER MOTOR
BARREL
1
LIQ. LINE
SOLENOID
COMP.
CONT.
COIL
BARREL
1
H20 SOL.
BARREL
1
SYR.SOL.
BARREL
1
CO2 SOL.
BARREL
2
CO2 SOL.
BARREL
2
H20 SOL.
BARREL
2
LIQ. LINE
SOLENOID
BARREL
2
SYR.SOL.
BARREL
1
DEFROST
SOLENOID
4
3
2
1
1
2
J1
J10
J11
J7
J9
J5
J6
J4
J3
J2
J6
CONTROL PCB A.
EMI FILTER
INTERFACE PCB A.
1
2
3
4
5
6
7
8
1
2
6
5
4
3
2
1
7
1 2 3 4
J14
J12
J15
J11
J5
J3
J1
J4
J2
J10
J9
L1
6
5
4
3
2
1
7
6
5
4
3
2
1
7
6
5
4
3
2
1
7
6
5
4
3
2
1
1
2
3
4
5
6
7
8
L2
J16
J13
J8
W1
1
2
3
4
J7
4
3
2
1
5
3
1
W1
MAGNATEK-CENTURY
PUMP
X1
A
B
CONTROL
TRANSFORMER
1
11
2
12
EMPTY
EMPTY
EMPTY
EMPTY - H20 PRESSURE SWITCH ACTIVE/JUMPER - H20 PRESSURE SWITCH BYPASSED
EMPTY
SERVICE/TEST ONLY
4
3
6
5
8
7
9
10
INTERFACE PCB A. W1 JUMPER BLOCK DETAIL
JUMPER BLOCK SHOWN ABOVE WOULD INDICATE A UNIT CONFIGURED
AS A MODEL 355, AIR COOLED WITH A H20 PRESSURE SWITCH.
OUT
BRN OUT
PCB A.
IN
IN
OUT