Electrolux 10 GN2/1 User Manual

Page of 3
Electrolux Blast Freezers 
Blast Chiller/ Freezer - 56 kg 10 GN2/1
Internet: http://www.electrolux.com/foodservice
HDBA040
2011-06-10
Subject to change without notice
SLIDE-IN RACK SUPP. BC+BCF 56KG 10 GN2/1
880075
PRINTER HACCP BASIC VERS-REF.ELECR.CONTR
881532
PLASTIFIED GRILL RILSAN GN 2/1
881030
PLASTIC COATED GRID-600X400 MM
880864
KIT TO CONVERT TO 10X2/1 ROLL-IN RACK
922202
KIT HACCP ADVANCED CONNECT. BC/BCF LW+CW
880183
80 MM PITCH SIDE HANGERS FOR 10X2/1 OVEN
922117
60 MM PITCH SIDE HANGERS FOR 10X2/1 OVEN
922123
4 WHEELS FOR BLAST CHILLERS
881097
3-POINT-SENSOR PROBE-BL.C/FREEZERS LW
880212
ACCESSORIES
1 SINGLE-SENSOR PROBE-BL.C/FREEZERS LW
1
INCLUDED ACCESSORIES
Power supply - V, phases, Hz
400 V, 3N, 50
Net weight - kg.
235
    installed-electric
2.88
Power - kW
    at evaporation temperature - °C
-30
Refrigerant power
Refrigeration power - W
2540
Refrigerant quantity - g.
3170
Refrigerant type
R404a
N° defrost in 24 hrs.
3/30'
Compressor power - HP
3
Max load capacity - trays h 65 mm - n°
6
Trays type
GN 2/1; 600x800
Door hinges
Right Side
    height
1640
    depth/with open doors
1010, 1755
    width
1000
External dimensions - mm
Cooling unit
Built-In
Gross capacity (D.I.N. 8952) - l.
560
    UK Guide lines - chilling / freezing
64, 56
    NF Regulations - chilling / freezing
43.2, 43.2
Productivity per cycle - kg.
Power supply
Electric
TECHNICAL DATA
RBC102
726046
CONSTRUCTION 
• 
Internal and external finishing in 304 
AISI stainless steel and backpanel in 
galvanized steel.
• 
High density polyurethane 
insulation, 60 mm tickness, HCFC 
free.
• 
Environmentally friendly: R404a as 
refrigerant fluid.
• 
Developed and produced in ISO 
9001 and ISO 14001 certified factory.
• 
Inner cell with fully rounded corners.
• 
Door equipped with removable 
magnetic gasket with hygienic design.
• 
Motors and fan waterproof 
protected IP23.
• 
Evaporator with antirust protection.
• 
Ventilator (fan) swinging hinged 
panel for access to the evaporator for 
cleaning.
• 
Automatic heated door frame.
• 
Thermostatic expansion valve to 
optimize the cooling unit efficiency.
• 
Adjustable feet 150 mm high.
• 
Stand alone printer as accessory.
• 
PC connection on request, gate RS 
485.
  
INSTALLATION 
• 
No water connections required.
• 
Waste water can be plumbed into 
drain, but can also be collected in an 
optional waste container.