2.  INSTALLATION 
 
2.1  Electrical connection 
 
Check that the mains voltage and power cable ratings are as per the 
information provided on the label attached to the oven door frame.  
This label must never be removed.
 
 
 
It is obligatory for the electrical system to be earthed according to the 
methods required by safety rules. 
 
 
If a plug and socket connection is being used make sure that the plug 
and socket are compatible. Avoid use of adapters and shunts as these 
could cause overheating and risk of burns. 
 
 
If a fixed connection is being used fit cable with an omnipolar circuit 
breaker with a contact opening gap equal to or greater than 3 mm in an 
easily accessible position near to the oven. 
 
 
 
 
 
For operation on 220-240V 
: use an 
H05RR-F / H05V2V2-F type three-core 
cable (3 x 1.5 mm
2
).
 
 
The cable end to be connected to the 
appliance must be provided with an ground 
wire (yellow-green) at least 20 mm longer. 
 
 
 
 
2.1.1
  Ovens with hob controls 
In the ovens with hob controls the power cable is not supplied. Use a 
H05RR-F or H05RN-F rubber-sheathed cable making sure that it does 
not come into contact with any external metal parts of the oven when 
routing. 
 
Remove rear cover by loosening relevant screws to gain access to the 
terminal strip. If necessary change jumper configuration as shown in the 
diagram and then connect wires making sure that the earth wire is at 
least 20 mm longer than the others. Secure power cable to oven by 
means of an appropriate fitting. 
 
 