The CO
2
 valves, shown in Figure 46, are located near the center of the unit and 
are mounted on a bracket to the bottom of the chassis. They control the injection 
of CO
2
 with the syrup/water combination to provide the final mixture for the prod-
uct. There are one of these solenoids for each barrel in the system. When working 
in this area, care should be taken not to damage or misalign the CO
2
 metering 
orfice. To replace one of these valves, perform the procedure in Table 48.
Figure 46. Side View of CO
2
 Pulse Valves 
Figure 47. Front View of CO2 Pulse Valves
Table 48
Step
Action
1
Disconnect power from the unit.
2
Disconnect the CO
2
 supply from the unit.
3
Remove the rear cover and side panels.
4
Carefully remove the tubing from the rear of the valve.
5
Remove the mounting tie-wrap from the rear of the valve.
6
Replace the valve.
7
Reverse the procedure to reinstall the valve into the unit.
Pulse Valve
(1 
OF
 3)
Mounting
Tie-Wrap
Pulse Valves