Toastmaster TMHP6 User Manual

Page of 16
3
GENERAL INSTALLATION DATA
 
 
This equipment is designed and sold for commercial use only by personnel trained and experienced 
in its operation and is not sold for consumer use in and around the home nor for use directly by the 
general public in food service locations. For equipment to be used by the general public, please 
contact the factory.
This gas appliance  is equipped for the types of gas indicated on the nameplate mounted on the  front 
panel. It is shipped adjusted for use on natural gas.
The installation of the Appliance should conform to the NATIONAL FUEL GAS CODE "ANSI 
Z223.1 - LATEST EDITION" AND ALL LOCAL GAS COMPANY RULES AND REGULATIONS.
IN CANADA INSTALLATION SHALL BE IN ACCORDANCE WITH THE CURRENT 
CAN/CGA-B149.1  NATURAL  GAS  INSTALLATION  CODE  OR  CAN/CGA-B149.2 
PROPANE INSTALLATION CODE AND LOCAL CODES WHERE APPLICABLE.
WARNING:  Improper  installation,  adjustment,  alteration,  service  or  maintenance 
can  cause  property  damage,  injury  or  death.  Read  the  installation,  operating  and 
maintenance instructions thoroughly before installing or servicing the equipment.
FOR YOUR SAFETY 
DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN 
THE VICINITY OF THIS OR ANY OTHER APPLIANCE. KEEP THE APPLIANCE AREA CLEAR 
AND FREE FROM COMBUSTIBLES.
This appliance, its pressure regulator and its individual shutoff valve must be disconnected from the 
gas supply piping system during any pressure testing of that system at test pressures in excess of /2 
PSIG. This appliance and its pressure regulator must be isolated from the gas supply piping system by 
closing its individual manual shutoff valve during any pressure testing of the gas supply piping system 
at test pressures equal to or less than 1/2 PSIG. For your protection, we recommend a qualified 
installing agency install this appliance. They should be familiar with gas installations and your local 
gas requirements. In any case, your gas company should be called to approve the final installation. 
In addition, there should be posted, in a prominent location, detailed instructions to be followed in the 
event the operator smells gas. Obtain the instructions from the local gas supplier.
LEVELING UNIT
Units are shipped with feet detached.  To attach feet, remove the grates, lay unit on it's side and screw 
feet into sockets on bottom.  Level unit by adjusting the (4) feet which have an adjustment of -3/4" for 
accurate and perfect line-up with other Star-Max series units. 
DO NOT REMOVE FEET.
GAS PIPING
Gas piping shall be new, clean and of such size and so installed as to provide a supply of gas sufficient 
to meet the full gas input of the appliance. If the appliance is to be connected to existing piping, it 
shall be checked to determine if it has adequate capacity. Joint compound (pipe dope) shall be used 
sparingly and only on the male threads of the pipe joints. Such compounds shall be resistant to the 
action of L.P. gases. WARNING: Any loose dirt or metal particles which are allowed to enter the gas 
lines on the appliance will damage the automatic valve and affect its operation. When installing this 
appliance, all pipe and fittings must be free from all internal loose dirt.
CAUTION
CAUTION