A Error Messages and Indicators 
Desktop Board DG35EC reports POST errors in two ways: 
•  By sounding a beep code 
•  By displaying an error message on the monitor 
BIOS Beep Codes 
The BIOS also issues a beep code (one long tone followed by two short tones) during 
POST if the video configuration fails (a faulty video card or no card installed) or if an 
external ROM module does not properly checksum to zero.  Table 14 lists the BIO
codes. 
Table 14. Beep Codes 
Beep Description 
3 No 
memory 
Siren 
Processor overheat (on reboot) 
BIOS Error Messages 
When a recoverable error occurs during the POST, the BIOS displays an error message 
describing the problem.  Table 15 gives an explanation of the BIOS error messages. 
Table 15. BIOS Error Messages 
Error Message 
Explanation 
PROCESSOR_THERMAL_TRIP_ERROR 
Processor was previously shutdown due to a thermal event 
(overheating). 
MULTI_BIT_ECC_ERROR 
The firmware has detected that a Multi-Bit ECC Error occurred. 
SINGLE_BIT_ECC_ERROR 
The firmware has detected that a Single-Bit ECC Error occurred. 
CMOS_BATTERY_ERROR The 
firmware has detected that a CMOS battery failure occurred. 
CMOS_CHECKSUM_ERROR 
The firmware has detected that a CMOS Checksum Error occurred. 
CMOS_TIMER_ERROR 
The firmware has detected that the system date/time has not 
been set. 
MEMORY_SIZE_DECREASE_ERROR 
The firmware has detected that the system memory has 
decreased. 
INTRUDER_DETECTION_ERROR 
The system chassis was opened. 
SPD_TOLER_ERROR 
SERIAL PRESENCE DETECT (SPD) device data missing or 
inconclusive.  Properly programmed SPD device data is required 
for reliable operation.   
MEM_OPTIMAL_ERROR 
The installed amount of memory in Channel A is not equal to the 
amount of memory in Channel B.  Maximum memory performance 
is achieved with equal amounts of memory installed in each 
channel.