GE PTD915WMWW Leaflet

Page of 2
Dimensions and Installation Information (in inches) 
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
Listed by 
Underwriters 
Laboratories
Under Oven Installation 
Warming Drawer Dimensions 
Undercounter Installation 
Specification Created 1/07
221128
Optional Accessories: 
JXPN2 – Optional Pan Set 
Accessory for Warming 
Drawer. Two commercial 
pans with lids (4” deep) 
ZXD30B –3/4” panel kit 
capability 
Undercounter Installation: A solid barrier must 
be installed at least 1” from the lowest point of the 
bottom of cooktop burner box to the top of the 
cutout. Use any solid material such as 1/4”-thick 
plywood. Allow at least 1/4” air gap between the 
barrier and the top of the warming drawer. See 
label on top of the warming drawer for approved 
cooktop models. 
Under Oven Installation: Additional clearance 
between cutouts may be required. Check to be 
sure that oven supports above the warming  
drawer location do not obstruct the required  
interior 23-1/2” depth and 9-1/4” height. 
Door handle protrudes 2-3/4” from door face. 
Cabinets and drawers on adjacent 45° and 90° 
walls should be placed to avoid interference with 
the handle.
Installation Information:
 Before installing, consult 
installation instructions packed with product for 
 current dimensional data.
KW Rating
120V
.45
Breaker Size
120V
15 Amps
25
1-1/2"  
Cabinet top
36"
Countertop
height
Electrical outlet  
42" max. from  
right side
Electrical outlet  
flush with side of  
cabinet 7" max.
Install 2x4 or 2x2  
anti-tip block against  
rear cabinet wall 9" from  
floor to bottom of block 
 
 
 
 
 
1" Min.*
9-1/4
28-1/2
Install a solid barrier  
below a cooktop  
(see note).
9
7
23-1/2 min.
Electrical
outlet 16" max.
from left side
Install a solid barrier  
and a 1/4" min. air gap  
above warming drawer.
Solid barrier
1/4" Air gap
298Dia1
9-1/4
Locate
electrical
outlet in
adjacent
cabinet
16" from
left side
or 42"
from right
side.
10-1/2
24" 
recommended
from floor 
for under 
countertop
installation
23-1/4
23-1/2" Min.
Inside
30
28-1/2
9
Allow 5/8"  
overlap on  
all sides
23-1/4
23-1/2"  
min.
1" Min. above toekick 
or adjust to oven 
installation height
2" min. 
A
Oven  
cutout
B
9-1/4
9
Allow 5/8" overlap 
on all sides
23-1/4
23-1/2"  
min.
1" Min. above toekick 
2" min. 
2x2 or 2x4  
anti-tip block  
against rear 
wall 9" from  
floor to bottom  
of block
2x2 or 2x4  
anti-tip block  
against rear 
wall 9" from  
floor to bottom  
of block
Oven  
cutout
9-1/4
10-1/2
30
28-1/2
10-1/2
PTD915BM/CM/WM 
GE Profile
 30" Warming Drawer
 
2x4 or 2x2
runners or solid
bottom
Install
2x4 or 2x2
Anti-Tip
Block 9" 
From Floor 
to Bottom
of Block
353Dia4
9