Emerson GXT2-1000RT230 User Manual
The Right Features In Just The Right Size
On-line design means zero transfer time from external
to internal power. When utility power fails, your critical
load remains supported by a seamless flow of power
from the GXT2.
to internal power. When utility power fails, your critical
load remains supported by a seamless flow of power
from the GXT2.
For maximum control, the GXT2 is custom configurable to
your needs using a specially designed Windows software
package. Offered in 700, 1000, 1500, 2000,3000, 4000,
and 6000 VA capacities, the GXT2 also provides easy serv-
iceability with user replaceable batteries. And all this is avail-
able in one of the most affordable UPS systems in its class.
your needs using a specially designed Windows software
package. Offered in 700, 1000, 1500, 2000,3000, 4000,
and 6000 VA capacities, the GXT2 also provides easy serv-
iceability with user replaceable batteries. And all this is avail-
able in one of the most affordable UPS systems in its class.
Quality Power
The Liebert GXT2 is a true on-line power source, so whatever
the quality of power coming in - the pure sinewave output
meets the exacting standards of your equipment.
Unlike other UPS technologies, the GXT2's design handles
all these potential power problems:
the quality of power coming in - the pure sinewave output
meets the exacting standards of your equipment.
Unlike other UPS technologies, the GXT2's design handles
all these potential power problems:
Power spikes and transients
EMI/RFI noise
Voltage sags and brownout conditions
Harmonics
Power-factor corrected loads
Outages
EMI/RFI noise
Voltage sags and brownout conditions
Harmonics
Power-factor corrected loads
Outages
Built-In Reliability
The GXT2 is designed from the inside out for maximum
reliability. It includes operating features that simply are not
available on other units in its price range:
reliability. It includes operating features that simply are not
available on other units in its price range:
• Power-factor corrected loads:
The GXT2 maintains stable voltage output even
with the power-factor corrected loads typical of
modern computer equipment.
with the power-factor corrected loads typical of
modern computer equipment.
• Frequency conversion:
Allows 60Hz input/50Hz output or 50Hz input/60Hz
output with no derating.
output with no derating.
• Unlimited external battery connectability:
Any number of 2U/4U battery cabinets can be added
to supply additional battery time.
to supply additional battery time.
• Internal automatic and manual bypass capability:
Assures continuity of power to critical loads during
system problems or maintenance.
system problems or maintenance.
• Optional Maintenance Bypass and Output
Power Distribution Box:
Allows for easy maintenance and safe operation on UPS
or connected equipment during installation and routine
service operations.
Allows for easy maintenance and safe operation on UPS
or connected equipment during installation and routine
service operations.
Top Trim
(2 pieces; tower
use only)
(2 pieces; tower
use only)
Status Indicators & Controls
Upper Bezel
Lower Bezel & Battery Access Door
Battery
Disconnect
Disconnect
External Battery Connector
UPS Output Circuit Breaker
DB-9 Communication
Port
Port
Removable Power
Distribution Box
Distribution Box
Fans
REPO Connector
Relay Card Slot
Serial Card Slot
(SNMP, OCWEB, USB)
(SNMP, OCWEB, USB)
DB-9 Communications Port
External Battery Connector
Output Sockets
Intellislot Port
Cooling Fan
AC Input
Support Base
GXT2 Tower Mode (2U version shown)