14.    3¼” x 10” Ducted Discharge Only: Remove Tape from damper flap and 
attach Damper/Duct Connector over knockout opening with screws removed 
in Step 4 under PREPARING HOOD. 
 
Make sure damper Pivot is nearest to Top/Back Edge of hood.
15.   7”Round Ducted Discharge Only: Re-install 7 ”Round Duct Plate removed 
in Step #1 under “PREPARING HOOD” section. Install a 7” round damper 
(purchase separately). Damper flap must open freely in direction of airflow 
(away from range hood).
notE:  To accommodate off-center ductwork, the Damper/Duct 
Connector can be installed up to 1-inch on either side of hood 
center or the 7” Round Duct Plate can be installed up to ½” on 
either side of hood center. In extreme off-center installations, one 
end of the duct connector may need to be trimmed to clear the 
electrical cable clamp.
UP TO 1”SIDE-TO-SIDEADJUSTMENT TAPE
TOP/BACK EDGE
DAMPER/DUCT
CONNECTOR (Vertical
discharge position shown)
PIVOT