GE ZV48R Installation Instruction

Page of 16
5
Advance Planning
DETERMINE INSTALLATION HEIGHT, DUCT COVER ACCESSORIES
Restaurant-Style Hoods
Restaurant-Style Hoods
without Warming Shelf Installed
with Shelf Installed
1
*Possible
*Possible
Actual
Hood
Hood
Ceiling Installation 6" Duct 12" Duct
Installation 6" Duct 12" Duct
Height
Height
Covers Covers
Height
Covers Covers
7' 11"
31"
1
1
37"
1
8' 0"
32"
1
1
32"
1
1
8' 0"
38"
1
8' 1"
33"
1
1
33"
1
1
8' 2"
34"
1
1
34"
1
1
8' 3"
35"
1
1
35"
1
1
8' 4"
30"
2
8' 4"
36"
1
1
36"
1
1
8' 5"
31"
2
37"
1
1
8' 6"
32"
2
32"
2
8' 6"
38"
1
1
8' 7"
33"
2
33"
2
8' 8"
34"
2
34"
2
8' 9"
35"
2
35"
2
8' 10"
30"
1
2
8' 10"
36"
2
36"
2
8' 11"
31"
1
2
37"
2
9' 0"
32"
1
2
32"
1
2
9' 0"
38"
2
9' 1"
33"
1
2
33"
1
2
9' 2"
34"
1
2
34"
1
2
9' 3"
35"
1
2
35"
1
2
9' 4"
30"
3
9' 4"
36"
1
2
36"
1
2
9' 5"
31"
3
37"
1
2
9' 6"
32"
3
32"
3
9' 6"
38"
1
2
9' 7"
33"
3
33"
3
9' 8"
34"
3
34"
3
9' 9"
35"
3
35"
3
9' 10"
30"
1
3
9' 10"
36"
3
36"
3
9' 11"
31"
1
3
37"
3
10' 0"
32"
1
3
32"
1
3
10' 0"
38"
3
These vent hoods must be installed 30" min. to
36" max. above the standard 36" high cooking
surface. When installed with the warming shelf,
allow 32" min. to 38" max. clearance. The exact
hood installation height is determined by the
ceiling height.
1.
Measure the exact ceiling height.
2.
Review the chart at right to determine the
range of possible hood installation heights that
can be accomplished with one or more duct
covers.
3.
Increase or decrease hood installation height to
accommodate the fixed 6" or 12" duct covers.
4.
Duct covers may be stacked, in various
combinations, to reach ceiling heights.
32" Min.
38" Max.
30" Min.
36" Max.
10" 
Ceiling 
Height
to Floor
Duct Cover(s)
Duct Cover(s)
10" 
Ceiling 
Height
to Floor
Note: When determining the installation height, consideration
must be given to the use of the warming shelf.
*Based on 36" countertop height.
Note: Additional duct covers may be used to reach higher ceilings.