Sony 2 User Manual

Page of 362
  
 Chapt
er
 16
 
Eng
inee
ring
 S
e
tu
p
290
Simple Connection of the MKS-8080/8082 AUX Bus Remote Panel
Simple Connection of the MKS-8080/8082 
AUX Bus Remote Panel
Procedure for Simple Connection
To carry out simple connection of the MKS-8080/8082 AUX Bus Remote 
Panel, use the following procedure.
For settings on the MKS-8080/8082, refer to the section “Making the Setting 
With Buttons (Setup Function)” in the Operation Manual for the MKS-8080/
8082.
1
Carry out initialization of the MKS-8080/8082 settings.
This can be done on the MKS-8080/8082 separately.
2
Set the MKS-8080/8082 station number in the range 2 to 17.
This can be done on the MKS-8080/8082 separately.
3
Set the S-BUS data link primary station to the CCP-8000 Center Control 
Panel.
Set the STATION ID switches S903 on the front of the CA-45 board in the 
SCU SLOT 1 to 001 (switch 1 only to the OPEN position).
4
In the Engineering Setup> System> Initialize menu, select PNL, and carry 
out a reset.
This carries out a restart, and when the restart is completed connection to 
the MKS-8080/8082 is possible.
5
In the Engineering Setup>Router/Tally> Router menu, set the position of 
the DVS-9000 system in S-BUS space.
Select the setting from SWR1 and SWR2, and set each of Source, 
Destination, and Level to 1.
Setting Status of the MKS-8080/8082 in Simple 
Connection
As a result of making the simple connection, the MKS-8080/8082 operates in 
AUX bus mode, and the settings are the following factory defaults.