Water Supply Requirements
Gather the required tools and parts before starting installation. 
Read and follow the instructions provided with any tools listed 
here.
IMPORTANT:
If you turn the refrigerator on before the water line is 
connected, turn the ice maker OFF.
All installations must meet local plumbing code requirements.
Use copper tubing and check for leaks. Install copper tubing 
only in areas where the household temperatures will remain 
above freezing.
TOOLS NEEDED: Flat-blade screwdriver, 
⁷⁄₁₆" and ¹⁄₂" open-end 
wrenches or two adjustable wrenches, 
¹⁄₄" nut driver and drill bit, 
cordless drill. 
NOTE: Your refrigerator dealer has a kit available with a 
¹⁄₄" 
(6.35 mm) saddle-type shutoff valve, a union, and copper tubing. 
Before purchasing, make sure a saddle-type valve complies with 
your local plumbing codes. Do not use a piercing-type or 
³⁄₁₆" 
(4.76 mm) saddle valve which reduces water flow and clogs more 
easily.
Water Pressure
A cold water supply with water pressure of between 30 and 
120 psi (207 and 827 kPa) is required to operate ice maker. If you 
have questions about your water pressure, call a licensed, 
qualified plumber.
Reverse Osmosis Water Supply
IMPORTANT: The pressure of the water supply coming out of a 
reverse osmosis system going to the water inlet valve of the 
refrigerator needs to be between 30 and 120 psi 
(207 and 827 kPa).
If a reverse osmosis water filtration system is connected to your 
cold water supply, the water pressure to the reverse osmosis 
system needs to be a minimum of 40 to 60 psi (276 to 414 kPa).
If the water pressure to the reverse osmosis system is less than 
40 to 60 psi (276 to 414 kPa):
Check to see whether the sediment filter in the reverse 
osmosis system is blocked. Replace the filter if necessary.
Allow the storage tank on the reverse osmosis system to refill 
after heavy usage.
If you have questions about your water pressure, call a licensed, 
qualified plumber.
Product Dimensions
Styles 1 and 2 - Euro Series and Overlay
Height dimensions are shown with the leveling legs extended 
to 
¹⁄₄" (6.35 mm) below the refrigerator drawers.
When leveling legs are fully extended to 1" (25 mm) below the 
refrigerator drawers, add 
³⁄₄" (19.05 mm) to the height 
dimensions.
The power cord is 60" (152.4 cm) long.
Style 1 - Euro Series
Style 2 - Overlay
Drawer Opening Dimensions
Dimensions vary based on model, as shown.
Style 1 - Euro Series
14
⁷⁄₈
"
(37.8 cm)
14
⁷⁄₈
"
(37.8 cm)
34
¹⁄₈
"
(86.7 cm)
³⁄₈
"
(1.0 cm)
14
⁷⁄₈
"
(37.8 cm)
14
⁷⁄₈
"
(37.8 cm)
34
¹⁄₈
"
(86.7 cm)
³⁄₈
"
(1.0 cm)
18
⁹⁄₁₆
"
(47.2 cm)
22
¹⁄₂
"
(57.2 cm)
21"
(53.3 cm)