KitchenAid KBRP36FKS02 User Manual

Page of 52
16
PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-LC400/LC400
Capacity: 400 Gallons (1514 Liters)
Service Flow Rate: 0.5 GPM (1.89 L/min.) @ 60 psi.
It is essential that operational, maintenance, and filter 
replacement requirements be carried out for the product to 
perform as advertised.
Model WF-LC400 The filter monitor system measures the 
amount of water that passes through the filter and alerts you 
to replace the filter. When 90% of the filter’s rated life is used, 
the filter indicator light changes from green to yellow. When 
100% of the filter’s rated life is used, the filter indicator light 
changes from yellow to red, and it is recommended that you 
replace the filter. Use replacement cartridge LC400,
part# 4396164. 2002 suggested retail price of $39.95 U.S.A./
$49.95 Canada. Prices are subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or 
of unknown quality without adequate disinfection before 
or after the system. 
Refer to the front cover or “Assistance or Service” section for 
the Manufacturer’s name, address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited 
warranty. 
Application Guidelines/Water Supply Parameters
Substance Reduction
Aesthetic Effects
Chlorine Taste/Odor
Particulate
U.S. EPA
MCL
N/A
N/A
Average
Influent
2.0 mg/L
610,000/mL*
 
Maximum
Effluent
N/A
N/A
Average
Effluent
0.04 mg/L
154/mL
Minimum %
Reduction
N/A
N/A
Average % 
Reduction
98%
99%
NSF Test 
Number
994707
994711
Contaminant
Reduction
U.S. EPA
MCL
Average
Influent
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average % 
Reduction
NSF Test 
Number
Cyst
Turbidity
99.95%**
0.5 NTU
89,250/mL*
29 NTU
6/mL
0.12 NTU
2.3/mL
0.09 NTU
99.993%
99.59%
99.997%
99.69%
994710
994710
Lead
: @ pH 6.5
Lead
: @ pH 8.5
0.015 mg/L
0.015 mg/L
0.16 mg/L***
0.16 mg/L***
0.001mg/L
0.002 mg/L
0.001 mg/L
0.001 mg/L
99.4%
98.8%
99.4%
99.4%
994708
994709
Tested and certified by NSF International against ANSI/NSF Standard 
42 for the reduction of Chlorine (Class I) Taste and Odor and against 
ANSI/NSF Standard 53 for the reduction of Lead, Cysts and Turbidity.
Water Supply
Water Pressure
Water Temperature
City or Well
30 - 120 psig (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)
*
**
 ***
Test  requirement is at least 100,000 particles/ml of AC Fine Test Dust.
Cyst performance is % reduction based on NSF Standard 53.
Test requirement is 0.15 mg/L ± 10%. These contaminants are not necessarily in your water supply. Performance may vary based on local water 
conditions.
® NSF is a registered trademark of NSF International.