Section 3 - Service and Repair
Too much ice
Ensure there is Permagum around the thermistor hole. If there is, 
proceed to the next step.
The control board is equipped with adjustment to adjust the level 
of ice in the bin for customer preference or when used in 
abnormal installations. With ice stacked to the desired level, check 
the bin temperature by holding WARMER and COLDER for five 
seconds. We’ll assume the display showed 38°F for this example. 
Go to service mode #24 and adjust the setting to that number. 
This will allow the bin to shut off at this ice level. This temperature 
needs to be checked after the door has been closed for at least 10 
minutes in order for the thermistor temperature to stabilize.
Too little ice
If this is a recurring issue, try adjusting service option #24 cooler 
in 1 or 2° increments until the desired level of ice is achieved.
Ice not sized to customer satisfaction
The thickness of the cubes can be adjusted per the ice thickness 
section of the manual.
Noise
Some noise from this unit is normal. You may hear the sound of ice 
dropping into the bin, especially when it is empty. The harvesting 
process involves flowing refrigerant and water through valves 
which may produce a rushing type sound during the harvest. The 
fan and compressor will produce a continuous low motor noise. If 
equipped, the P60 pump will produce noise at regular intervals as it 
empties water from the unit. If any of these is objectionable the 
unit has an Office mode which can be entered for three hours at a 
time. During this mode the unit will not produce ice; however, the 
drain pump will continue to operate.
No water in trough
Ensure the stand pipe is fully inserted into the trough.
Check the water valve to see if it is filling the unit.
Watch the water flow over the mold to see if excess water is being 
splashed out of the trough. This could be the result of improper 
leveling.
Ice does not release from evaporator
This could be caused by improper leveling or the unit is in need of 
cleaning.
Poor ice quality
This can be caused by poor incoming water quality. The 
CLRCO2175 is designed to produce clear ice in most water; 
however, abnormal water conditions may result in the need for 
further filtering.
Water in ice bin
A defect in the drain from the unit will cause water to stop 
draining from the unit.
Display is showing something other than “SP (38),” 
“ER” or “CL.”
Push one of the keys to see if the display is reset.
Turn unit on and off via the display pad.
Unplug unit, wait one minute and plug back in. If any of these steps 
returns the unit to operation the unit was probably accidently 
entered into a service mode.
Display is showing a random snaking of characters 
or a degree symbol is flashing.
The unit is in a special showroom mode. Hold the COLDER key 
and press LIGHT three times to exit.
Display not illuminating but unit operating
First try to plug and unplug the unit. If the display still does not 
illuminate there is a four-wire pin connector running from the main 
board in the base to the display board. One of the wires is 
disconnected or damaged.
Unit is not operating—no cooling—no fans.
Unplug unit and plug back in. If main board beeps when plugging in 
the unit then this is most likely a system problem, not a board 
issue.
If board does not beep when plugging in the unit, check the power 
supply to ensure the outlet is working. Also, check the fuse on the 
circuit board.
Refrigerator not cooling but ice maker working
Check to ensure the refrigerator thermistor is working properly. 
Ice maker not operating—no water flowing over 
mold
The refrigerator needs to be at or below set-point (or 42°F) to 
start the ice-making process. If the unit is cool enough there could 
be a defective bin thermistor, defective condenser thermistor or 
defective solenoid coil.