Dometic DS 300 H User Manual

Page of 8
5
3. Cleaning
Clean the refrigerator thoroughly at intervals, as
necessary.  Remove  the  shelves;  these,  the
cabinet interior and the door should be washed with a
warm  solution  of  sodium  bi-carbonate.  Finally  wipe
over with a cloth rinsed in warm water only, and dry
with  a  clean  cloth.  Do  not  wash  any  plastic  parts  in
water that is more than hand warm, and do not expose
them to dry heat. The outside of the cabinet should be
wiped down regularly with a clean, damp cloth.
NEVER  USE  STRONG  CHEMICALS  OR  ABRASIVE
CLEANING  MATERIALS  ON  ANY  PART  OF  THE
CABINET.
4. Positioning the appliance
When first using this refrigerator please consider the
following points:
ENSURE REFRIGERATOR IS LEVEL
THE PIPEWORK AT THE BACK GETS HOT IN USE
THE  REFRIGERATOR  HAS  NO  'MOTOR'  AND  IS
THEREFORE VIRTUALLY SILENT
ALLOW  AT  LEAST  3  HRS.  FOR  SIGNS  OF
COOLING
During the refrigeration process, the appliance
gives  off  heat  from  the  condenser  (under  the
upper part of the rear cover) into the surrounding air.
The  more  ventilated  the  condenser  is,  the  more
effective the refrigeration will be.
The other condition for satisfactory operation is that
the appliance stands on a flat surface. This is best
seen  by  placing  a  glass  of  water  on  top  of  the
appliance.
It  is  important  that  the  appliance  is  not  directly
exposed to radiated heat (sunlight, radiator, near an
oven, etc.).
Please  do  not  place  the  refrigerator  onto  thick
carpet!
4.1. Installation instructions
This version is supposed to be freestanding. Cooling
unit  room  cover  protects  from  the  hot  parts  of  the
cooling unit. Foot frame with grilles ensures sufficient
ventilation.
5. Using the appliance
To start the refrigerator connect the plug to the socket
outlet  and  switch  on  the  socket.  The  cooling  fins
should  show  signs  of  cooling  after  about  1-2  hours
depending on ambiant temperature.
5.1. Initial operation
The device must be plugged into a properly earthed
socket.
The  miniCool  starts  automatically  with  a  self-test.
The LED illuminates after plugging-in several times
and  after  that  continuous  light  can  be  seen  if  the
door is open.
The miniCool achieves its operating temperature
after several hours.
5.2. Temperature regulation
The  usual  setting  required  is  in  the  region  of  the
middle of the thermostat knob (Fig. 6), but this can
vary with conditions of load and installation. If it is
found necessary to alter the setting,the knob can
be turned to a higher symbol to produce a colder
temperature,  or  a  lower  symbol  to  produce  a
warmer temperature. The effect of any adjustment
can be checked by means of a thermometer after
leaving  the  refrigerator  operating  for  a  further
period to settle down again.
Figure 3.
6. Thermometer
(Fig. 4)
Refer  to  the  separate  instruction  leaflet  supplied
with  the  thermometer.  The  thermometer  can  be
stood up using the attached stand or alternatively it
can be fixed  to the refrigerator door, in which case
the sensor wire should be arranged so that it is not
stretched or damaged when the door is opened.
The  temperature  sensor  is  located  inside  the
refrigerator in the upper left corner in front of the
evaporator.
The  display  will  then  show  the  current,  maximum
and minimum temperature inside the refrigerator.
After  the  first  pull  down  of  the  refrigerator  (allow
four  hours)  please  make  a  "reset"  on  the
thermometer  because  otherwise  it  will  keep  as
"maximum" the ambient temperature.
If  you  find  lower  than  +2  °C  or  even  negative
temperature as a minimum on the screen, it must
have  occured  due  to  a  cutout  in  the  electrical
circuit.  In  these  circumstance's  the  electronic
thermostat  will  make  a  restart  and  start  to  cool
down  the  refrigerator,  without  monitoring  the
refrigerator  for  45  minutes.  If  you  reset  the
thermometer again (1-2 hours later) and the normal
+2 ... +8 °C is shown then you can be sure that the
medincines have not been damaged or frozen.
The  more  medicines  you  store  in  the  refrigerator
then reduces the hazard of freezing, if the unit has
a short period of time undercooling.
We  take  no  responsibility  for  damage  to
vaccines through freezing, if there has been a
cutout  in  the  electricity  for  a  short  period  of
time.
It is important to reset the thermometer regularly to
ensure that the temperature is maintained between
2 °C and 8 °C.