Estate 2315225 User Manual

Page of 40
12
PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model WF-NL300/NL300 capacity 300 Gallons (1136 Liters) 
Model WF-L500/L500 capacity 500 Gallons (1893 Liters)
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of 
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for 
water leaving the system, as specified in ANSI/NSF 42/53. 
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F 
(17.2°C).
It is essential that operational, maintenance, and filter 
replacement requirements be carried out for the product to 
perform as advertised.
Model WF-NL300: The concentration of the indicated 
substances in water entering the system was reduced to a 
concentration less than or equal to the permissible limit for 
water leaving the system as specified in ANSI/NSF 42 and 53. 
Change cartridge at least every 6 months. Use replacement 
cartridge NL 300, part #4396508. 2005 suggested retail price 
of $32.99 U.S.A./$44.95 Canada. Prices are subject to change 
without notice.
Model WF-L500: The concentration of the indicated 
substances in water entering the system was reduced to a 
concentration less than or equal to the permissible limit for 
water leaving the system as specified in ANSI/NSF 42 and 53. 
The filter monitor system measures the amount of water that 
passes through the filter and alerts you to replace the filter. 
When 90% of the filter’s rated life is used, the filter indicator 
light changes from green to yellow. When 100% of the filter’s 
rated life is used, the filter indicator light changes from yellow 
to red, and it is recommended that you replace the filter. Use 
replacement cartridge L500, part #4396508. 2005 suggested 
retail price of $32.99 U.S.A./$44.95 Canada. Prices are 
subject to change without notice.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of 
unknown quality without adequate disinfection before or after 
the system. 
Refer to the “Assistance or Service” section for parts and 
service availability or for the Manufacturer’s name, address 
and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited 
warranty. 
Note that while the testing was performed under standard 
laboratory conditions, actual performance may vary. Systems 
must be installed and operated in accordance with 
manufacturer’s recommended procedures and guidelines.
System tested and certified by NSF International against 
ANSI/NSF Standard 53 for the reduction of Lead; and 
against Standard ANSI/NSF 42 for the reduction of Taste 
and Odor, Chlorine Class I.
Substance Reduction
Min. Required % 
reduction
Average
Influent 
mg/L
Influent Challenge 
Concentration
Max. Effluent 
mg/L
Product 
Water mg/L
Min.% 
Reduction
Average% 
Reduction
Chlorine Taste/Odor
50%
1.9
2.0 mg/L ± 10%
0.05
0.05
97.4
97.4
Contaminant
Reduction
Max. Permissible 
Concentration mg/L
Average
Influent 
mg/L
Influent Challenge 
Concentration
Max. Effluent 
mg/L
Product 
Water mg/L
Min.% 
Reduction
Average% 
Reduction
Lead: @ pH 6.5
Lead: @ pH 8.5
0.01
0.01
0.15
0.15 
0.15 mg/L ± 10%
0.15 mg/L ± 10%
0.001
0.003
0.001
0.001
99.30
97.90
99.30
99.00
Application Guidelines/Water Supply Parameters
Water Pressure
Water Temperature
Rated Service Flow
30 - 120 psig (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 Lpm)
® NSF is a registered trademark of NSF International.