e. Malfunctioning 
fans 
 
f. 
Improper evaporator or 
condenser airflow 
g. Dirty 
Condenser 
h. Iced 
evaporator 
i. Refrigeration 
system 
restriction 
j. Sealed 
system 
problem 
 
k.  Undercharge or overcharge 
 
intake side  
e. Check for both evaporator and 
condenser fans  
f. 
Check for air restrictions 
 
g. Clean 
condenser 
h.  Defrost and reset temperature 
i. 
Call service for checking  restrictions
j.  Call service for checking loss of 
refrigerant or restrictions 
k.  Call service to add or remove 
refrigerant 
 
5.Unit running 
too long or 
continually
 
a.  Improper room insulation & seal 
 
b. Exhaust restricted 
 
 
 
c.  Room too large 
 
d. Ambient temperature higher > 
90
°
e. Dirty Condenser 
 
a.  Check for insulation, gasket and door 
opening 
b.  Leave minimum 3 feet clearance for 
the exhaust side and leave minimum 
1 foot clearance for the fresh air 
intake side 
c.  Check for excessive size or increase 
setting   
d. Check for installation location or 
increase setting 
e. Clean condenser 
 
7.Evaporator  
icing 
a.  Evaporator air flow restriction 
b.  Unit not stopping due to air leak, 
high ambient temperature or low 
setting 
c.  Low ambient temperature 
d.  Bad thermostat or sensor 
e. Refrigerant 
leak 
f. 
Expansion valve blockage 
a.  Check for fans 
b. Check for seal, door opening, 
ambient temperature and setting 
 
c.  Defrost the unit 
d.  Check for thermostat and sensor 
e.  Check for sealed system leakage 
f. 
Check for low side pressure 
 
8.Circuit 
tripping  
a.  Incorrect fuse or breaker 
b. Incorrect 
wirings 
c. Failed 
components 
 
a.  Check for proper fuse or breaker 
b.  Check for wirings and connections 
c.  Call service  
 
9.Noisy 
operation 
a.  Mounting area not firm 
b. Loose 
parts 
 
 
c.  Compressor overloaded due to 
high ambient temperatures or 
airflow restriction 
d. Malfunctioning 
components 
 
a.  Add support to improve installation 
b.  Check fan blades, bearings, cabinet 
washers, tubing contact and loose 
screws. 
c.  Check for airflow blockage 
 
 
d.  Call service for checking Internal 
loose, inadequate lubrication and 
incorrect wirings