be reduced by installing a rabge hood that projects horizontally a minimum of 5 inches beyond the 
bottom of the cabinets 
It’s always compulsory to install the riser even for an island installation 
ATTENTION: A manual valve shall be installed in an accessible location in the gas line external to the 
appliance for the purpose of turning on or shutting off gas to the appliance 
WARNING: Do not use aerosol sprays in the vicinity of this appliance while it is in operation 
Requirements 
Room ventilation – Location and venting. 
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in 
conformity with the appropriate national and local standards. 
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be 
installed in conformity with the appropriate national and local standards. 
 
INSTALLATION MANUAL 
ANTI-TIP STABILlTY DEVICE INSTALLATION INSTRUCTIONS 
1. The anti-tip bracket have to be  installed to the rear wall as shown. The height for the bracket location from 
the floor has to be determined after the range legs have been adjusted to the proper installation height - as 
shown in the installation instructions – and after  the range has been leveled.  
2. Measure from the floor to the bottom of the anti-tip bracket location on the back of the range. 
3. Position the two anti-tip brackets on the wall at the measured dimension plus 1/8" (0.32 cm). The brackets 
have to be placed at 2”5/16 (6,0 cm) from the side of the range. The distance between the two bracket is  
43”1/4 (109,8 cm) clearance. Secure with suitable inserts. 
4. Slide the range against the wall until the brackets are fully inserted into the holes on the backside of the 
range..