12-02
21
34615 Rev G
NOVUS B-VENT INSTALLATION INSTRUCTIONS
3. VENTING SYSTEM INSPECTION
The appliance and venting system should be inspected
before use, and at least annually, by a qualified field
service person, to ensure that the flow of combustion
and ventilation air is not obstructed.
4. CLEANING THE GLASS
See Figure 29.
Never operate this appliance without the glass properly
secured in place or if the glass is broken.
In the event of glass breakage, carefully remove the
glass  frame. This  will  allow  the  removal  of  all  glass
fragments  and  sheet  metal  edge  protection  strips.
Vacuum all remaining glass pieces with a shop vac.
DO  NOT  VACUUM  IF  PIECES ARE  HOT!  Replace
glass  with  only  a  Heatilator  glass  panel  assembly
ordered direct or through your local distributor. Never
use substitute material. Only fully tempered soda lime
safety glass may be used on this appliance.
5. LOG REMOVAL/REPLACEMENT
If removal of the logs becomes necessary, remove the
two screws at the front of the grate. Grasp the two outside
upright grate bars. Pull the log set toward the front and
up, off the burner. See Figure 30.
To replace the log set, grasp the two outside upright grate
bars. Push and lower the log set onto the burner pan,
making sure the back of the left most grate bar slides
through  the  grate  mounting  bracket  attached  to  the
hearth pan. Attach the two screws at the front of the
grate.
Figure 29 - Glass Cleaning
Figure 30 - Log Removal
Safety Note:
Handle  glass  with  care  to
avoid  striking,  scratching  or
slamming  shut.  NEVER
clean glass when hot. Keep
children  and  pets  a  safe
distance away.