NOVUS B-VENT INSTALLATION INSTRUCTIONS
G.  FINISHING
1. COMBUSTIBLE FINISHING MATERIAL
Material made of or surfaced with wood, compressed
paper, plant fibers, plastics, or any material capable of
igniting  and  burning,  whether  flame  proofed  or  not,
plastered or unplastered (this includes drywall).
2. NONCOMBUSTIBLE FINISHING MATERIAL
Material which will not ignite and burn. Such materials
are those consisting entirely of steel, iron, brick, tile,
concrete, slate, glass or plasters, or combination thereof,
or have a UL Fire rating of Zero (0).
3. HIGH TEMPERATURE SEALANT MATERIAL
Sealants that will withstand high temperatures: General
Electric  RTV103  (Black)  or  equivalent.  Rutland,  Inc.
Appliance Mortar #63, or equivalent.
A high temperature sealant, 1/8” inch wide minimum,
must be used to close off gaps between the appliance
and facing to prevent cold air leaks. See Figure 17.
Note: 
If an optional fan or hand held remote control
are to be used, wiring must be done prior to finishing
to avoid reconstruction.
Note: 
The  remote  wall  switch  must  be  wired  prior  to
applying  the  finishing  material  in  order  to  avoid
reconstruction.
Figure 17 - Finishing Materials
WARNING!
Grilles on this appliance cannot, in any way, be cov-
ered as it may create a fire hazard.
H.  APPLIANCE PREPARATION
Figure 18 - Hood Placement
1. ATTACHING THE HOOD
The hood is to be located above the glass panel. The
hood must be attached or a fire hazard may result.
Locate the four screws just inside the upper section of
the appliance. Position the hood and slide into position.
Tighten the four screws. See Figure 18.
2. UPPER GRILLE PANEL REMOVAL
Grasp the upper grille panel and remove the rubber
pins holding the grille. See Figure 19.
3. CONTROL ACCESS PANEL REMOVAL
Release the spring pin on the right hand side of the
control access panel. See Figure 20.
Figure 19 - Upper Grille Panel Removal
4. GLASS AND SCREEN REMOVAL
See page 21 of this manual.