NOVUS B-VENT INSTALLATION INSTRUCTIONS
1. APPLIANCE  LOCATIONS  AND  SPACE
REQUIREMENTS
Figure 1 illustrates a variety of ways the appliance may
be  located  in  a  room.  The  NOVUS  Series  may  be
installed directly on the floor or raised on a hearth. These
appliances are certified for installation in a bedroom, bed/
sitting rooms or bathrooms in the U.S. and Canada,
provided that the bedroom or bathroom has a volume
of at least 1350 cubic feet.
Common venting of this gas appliance with other gas
appliances is not allowed in multifamily dwellings.
2. CLEARANCES
Figure 2 shows all clearances that must be maintained
around the appliance.
Figure 1 - Appliance Locations
Figure 3 shows a typical framing of this appliance using combustible materials. All required clearances to combustibles must
be adhered to. Mantel height is measured from the base of the appliance.
CAUTION:
Wear gloves and safety glasses for protection.
C.  FRAMING
Figure 2
Appliance Clearances to Combustible Materials
Figure 3 - Framing
WARNING!
To prevent contact with sagging or loose insulation,
the appliance must not be installed against vapor
barriers or exposed insulation.