IBM Series 1500 User Manual

Page of 172
 Symptom-to-FRU Index
The Symptom-to-FRU Index lists the symptoms and errors
and the possible causes. The most likely cause is listed
first.
Note:  Perform the FRU replacement or actions in the
sequence shown in the FRU/Action columns. If a
FRU does not solve the problem, put the original
part back in the computer. Do not replace a non-
defective FRU.
This index can also be used to help you decide which
FRUs should be available when servicing a computer.
Numeric error codes show the errors detected in POST or
system operation (runtime). In the following error codes, X
can be any number.
If no codes are available, use narrative symptoms.
If the symptom, is not listed, go to “Undetermined
Problems” on page 38.
Note:  For any IBM device not supported by the diagnostic
codes in this ThinkPad computer, see the manual
for that device.
Numeric Error Codes and Messages
Error
Code
Message
FRU/Action in Sequence
006
Equipment
Configuration
Error
Enter BIOS Utility and
execute "Load Setup
Default Settings"; then
reboot the system.
040
Diskette Drive
Controller
Error
Ÿ
Go to “FRU tests” on
page  48.
 
Ÿ
Diskette drive
 
Ÿ
System board
070
Real Time
Clock Error 1
Ÿ
Backup battery (RTC
battery)
Ÿ
Enter BIOS Utility and
execute "Load Setup
Default Settings"; then
reboot the system.
 
Ÿ
System board
071
CMOS Battery
Bad 4
Ÿ
Backup battery (RTC
battery)
Ÿ
Enter BIOS Utility and
execute "Load Setup
Default Settings"; then
reboot the system.
 
Ÿ
System board
   
ThinkPad i Series 1400/1500
33