Smeg GCS70XG User Manual

Page of 17
 
Instructions for the installer 
 
26 
ELECTRICAL CONNECTION 
 
 
 
   
 
 Make sure that the voltage and capacity of the power line conform to 
the data shown on the plate located under the casing. Do not remove 
this plate for any reason. 
 
   
 
  The plug on the end of the supply cable and the wall socket must be the 
same type and conform to the current electrical system regulations. 
Check that the power line is adequately grounded. 
 
   
 
  On the power line, install an omnipolar cut-off device with contact cut-off 
distance greater than or equal to 3 mm, located in an easily accessible 
position near the unit. 
 
   
 
  Do not use reducers, adapters or shunts. 
 
   
 
  If the power cable is replaced, the wire section on the new cable must 
not be less than 1.0 mm 
2
 
(3 x 1.0 cable), keeping in mind that the end 
to 
be connected to the hob must have the ground wire (yellow-green) 
longer by at least 20 mm. Use only H05V2V2-F cable or similar which 
has a maximum temperature of 90°C. Any replacement needed should 
be carried out by a specialised technician who should make the mains 
connections according to the following diagram. 
L = brown 
N = blue 
= yellow-green 
 
   
 
 
 
 
   
 
  The manufacturer will not be liable for any damage to persons or 
property caused by non-observance of the above instructions or 
deriving from the tampering of even a single part of the hob.