Smeg SUK81MFA5 User Manual

Page of 20
 
 
Instructions for the installer 
 
4.  FINAL OPERATIONS 
 
After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the 
grids. 
 
 
Following adjustment to a gas other than the preset one, replace the gas adjustment label 
fixed to the appliance with the one corresponding to the new gas. This label is in the packet 
together with the nozzles. 
 
 
4.1 Regulation of the hob burner minimum level for natural gas 
 
Light the burner and turn it to the minimum position  . Extract the gas 
tap knob and turn the adjustment screw at the side of the tap rod until 
the correct minimum flame is achieved.  
Replace the knob and check burner flame stability: (rapidly turning the 
knob from maximum to minimum position, the flame should not go out). 
Repeat the operation on all the gas taps. 
 
 
 
 
 
 
For models with valves, keep the knob at minimum level for about 1 minute to keep the flame 
lit and to activate the safety device. 
 
 
4.2 Regulation of the hob burner minimum level for LPG 
In order to adjust the minimum with LPG, the screw at the side of the tap rod must be turned 
clockwise all the way. 
The bypass diameters for each individual burner are shown in paragraph “3.2 Burner and 
nozzle characteristics table". Once the regulation has been completed, restore the seal on the 
by-passes using paint or similar materials. 
 
4.3 Mounting the rear top skirtboard (where applicable) 
 
•  Loosen nuts B
•  Position the skirt above the top, taking care to align pins C with holes D
•  Secure the skirt to the top by tightening screws A
 
 
 
 
10