Instructions for the installer 
 
30
 
 
For operation on 380-415 V 3N
: use an H05RRF / H05RN-F type 
five-core cable (5 x 1,5 mm
2
). 
This type of connection cannot be used for models with 5 plates. 
 
 
 
 
For operation on 380-415 V 2N
: use an H05RR-F / H05RN-F type 
four-core cable (4 x 2,5 mm
2
). 
 
 
 
 
 
For operation on 220-240 V 3
: use an H05RR-F / H05RN-F type 
four-core cable (4 x 2,5 mm
2
). 
 
 
 
For operation on 220-240 V
: use an H05RR-F / H05RN-F type three-
core cable. 
(3 x 2.5 mm
2
 
: cooking hob with 4 plates) 
(3 x 4 mm
2
 
: cooking hob with 5 plates)
 
 
The cable end to be connected to the appliance must be provided with 
an earth wire (yellow-green) at least 20 mm longer. 
 
Read the connection layout plate underneath the appliance with care.
 
 
If the appliance you have purchased is not fitted with a mains power lead a power lead resistant to a 
temperature of at least 90°C must be used. 
Otherwise, the electrical safety of the appliance may be put at risk. 
 
The manufacturer declines all responsibility for damage to persons or things caused by non-
observance of the above prescriptions or by interference with any part of the appliance. 
 
Warning: pass the power cable through hole “A” and fit 
the cable clamp plate after making the electrical 
connection. 
To fit the plate, simply use the provided bolts to secure it 
under the casing as shown in the figure.
 
TYPE 1 TERMINAL BOARD  
 
 
Warning: close the cable clamp after making the 
electrical connection. Close the terminal board cover by 
twisting it down. 
 