Smeg SP106VLIR User Manual
Instruction for the installer
9
3.2 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG
–
G30/G31
28/37
mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
Flowrate
(W)
Flowrate
g/h G30
Flowrate
g/h G31
Auxiliary
1
50
30
350
73
71
Semi-rapid
1.75
65
33
450
127
125
Rapid
2.5
79
45
800
181
179
Triple crown
3.5
94
65
1500
254
250
Oven
5.2
110
59
1200
377
371
Grill
4
100
//
//
290
285
Burner
Rated
heating
capacity
(kW)
NATURAL GAS –
G20
20
mbar
Nozzle diameter
1/100 mm
Reduced Flowrate
(W)
Auxiliary
1
72
350
Semi-rapid
1.75
97
450
Rapid
2.5
108
800
Triple crown
3.5
133
1500
Oven
5.2
164
1200
Grill
4
150
//