Instructions for the installer 
 
2.5 Discharge of combustion products 
 
 
Discharge of combustion products must be guaranteed by means of 
hoods connected to a natural draught flue with certain efficiency, or by 
means of forced aspiration. 
An efficient aspiration system requires careful planning by a specialist 
capable of installing it, respecting the positions and distances prescribed 
by standards. After installation, the installer must issue a certificate of 
conformity. 
 
3. GAS CONNECTION 
 
This appliance is suitable for installation with Natural 
Gas or LPG (propane). Refer to page 12 for the 
relevant burner pressure and appropriate injector 
sizes. When the appliance is to be connected to 
Natural Gas then the pressure regulator supplied must 
be fitted to the gas inlet. A test point (for checking the 
gas pressure) is supplied either with the regulator or as 
a separate fitting in the case of LPG (propane) 
appliances. 
Connection of the appliance to the gas supply must be 
in accordance with the requirements of AS5601. A ½” 
BSP connector at the inlet is recommended and the 
gas supply line to the appliance must be of adequate 
length to allow sufficient withdrawal of appliance for 
service or disconnection and be: 
1.  annealed copper pipe or; 
2.  flexible hose according to AS/NZ1869 & be at 
least Class “B”, 10 mm diameter. 
 
The appliance must be installed with provision to allow the gas to be 
turned off and disconnected for servicing and removal of the appliance 
as required from the gas supply. 
Before the appliance is operated make certain all relevant parts are 
placed in the correct position. 
When the installation is completed the installation connections of 
appliance will require to be leak tested, the burner operating pressure 
and flame checked and adjusted. 
Warranty service calls do not cover these adjustments! 
To check the operating pressure of the appliance it is recommended at 
least 2 large size burners are used. Ensure appliance is secured to wall 
when installation is completed. 
N.G. The regulator supplied must be fitted to the ½ BSP thread at the 
rear of the appliance. An approved manual shut-off valve must be 
installed. The N.G. regulator must be checked and adjusted to 1.0kPa 
after installation. 
 
12