Smeg APC61BVG User Manual

Page of 24
 
 
Instruction for the installer 
 
11
 
 
 
4  FINAL OPERATIONS 
 
   
 
  After replacing the nozzles, reposition the flame-spreader crowns, the burner caps and the grids. 
 
   
 
  Following adjustment to a gas other than the preset one, replace the gas adjustment label fixed to the
appliance with the one corresponding to the new gas. This label is in the packet together with the
nozzles. 
 
   
 
 
4.1  Regulation of the hob burner minimum level for natural gas 
 
   
 
  Light the burner and turn it to the minimum position  . Extract the gas tap 
knob and turn the adjustment screw at the side of the tap rod until the
correct minimum flame is achieved.  
Replace the knob and check burner flame stability: (rapidly turning the
knob from maximum to minimum position, the flame should not go out).
Repeat the operation on all the gas taps. 
 
   
 
  For models with valves, keep the knob at minimum level for about 1 minute to keep the flame lit and to 
activate the safety device. 
 
   
 
 
4.2  Regulation of the hob burner minimum level for LPG 
 
 
 
 
  For regulating the minimum with LPG, the screw at the side of the tap rod must be turned clockwise all
the way. 
The bypass diameters for each individual burner are shown in paragraph “3.2 / 3.3 Burner and nozzle 
characteristics table”. Once the regulation has been completed, replace the seal on the by-passes 
using paint or similar materials. 
 
   
 
 
4.3  Regulation of the oven burner minimum level 
 
 
 
 
  The oven thermostat is equipped with a by-pass to regulate the minimum level, which is visible 
underneath the thermostat knob. 
When the gas type is changed, the by-pass should be regulated as follows: 
1.  Turn on the oven burner to maximum for 10/15 minutes with the door closed and without the floor.
Turn the knob to the minimum temperature, remove the knob and regulate using a flat
screwdriver. 
2.  For LPG turn the by-pass screw clockwise as far as it will go. The by-pass diameter is shown in 
the paragraph “3.2 / 3.3 Burner and nozzle characteristics table”. 
3.  For natural gas, regulate the by-pass so that turning the thermostat knob from minimum to
maximum the flame remains stable and constant. Once the regulation has been completed,
replace the seal on the by-pass using paint or similar materials. Close the oven door and make 
sure that the burner stays on minimum.