4. DESCRIPTION OF CONTROLS
After changing the nozzles, put the pan stands, the burner caps and flame
diffuser rings back in place.
After adjusting for use of a gas other than the gas used for testing the
appliance, replace the gas setting label on the appliance with the label for
the new gas. The label is supplied in the bag with the nozzles.
4.1
Adjusting the minimum setting for natural gas
Light the burner and turn it to the minimum setting
 Remove the gas tap knob and adjust the regulator
screw inside or beside the tap rod (depending on the
model) until an even minimum flame is obtained. Put
the knob back in place and check the stability of the
burner flame (the flame must not go out when the
knob is turned quickly from the maximum to the
4.2
Adjusting the minimum for bottled gas
To adjust the minimum level when using bottled gas, the adjuster screw
inside or beside the tap rod must be turned fully clockwise (depending on
the models).
The diameters of the bypasses for each individual burner are stated in
point "3.2 Burner and Nozzle Data Tables".