Simrad AP26 User Manual

Page of 152
Installation 
20221586B
 59 
LINEAR DRIVE UNITS 
MODEL MOTOR 
VOLTS 
AUTO-
PILOT 
COM-
PUTER 
MAX 
STROKE 
mm (in.) 
PEAK 
THRUST 
kg (lb.) 
MAX 
RUDDER 
TORQUE 
Nm  
(lb.in.) 
HARD-
OVER 
TIME  
sec. 
(30% load) 
PWR. 
CON-
SUMP. 
TILLER 
ARM 
mm 
(in.) 
MLD200 12V 
AC10 
300 
(11,8) 
200 
(440) 
490 
(4350) 
15 1,5-6 
263 
(10,4) 
HLD350 12V 
AC10 
200 
(7,9) 
350 
(770) 
610 
(5400) 
12 2,5-8 
175 
(6,9) 
HLD2000L 12V 
AC20 
340 
(13,4) 
500 
(1100) 
1460 (12850)
19 
3-10 A 
298 
(11,7) 
HLD2000D 24V AC20 
200 
(7,9) 1050 
(2310) 
1800 
(15900) 
11 3-10 
175 
(6,9) 
HLD2000LD 24V AC20 
340 
(13,4) 1050 
(2310) 
3180 
(28000) 
19 3-10 
298 
(11,7) 
MSD50* 12V 
AC10 
190 
(7,5) 
60 
(132) 
– 15 
0,8-2 
– 
Steering gear interface: Connects to quadrant or tiller. 
* For stern drive power assisted steering only. 
1. The motor voltage is stepped down by the autopilot computer 
when operating from 24V or 32V mains. 
2. The specified autopilot computer is necessary to achieve max 
drive unit capacity. 
3. Recommended operational thrust or torque is 70% of listed 
peak value. 
4. Typical average power consumption is 40% of listed 
maximum value.