Managing the System 
Page 6-19
Programming from a PC with SPM 
6
Types of PC Connections
6
There are three ways to connect the PC to the control unit:
Direct Local Connection. For a direct local connection, you must connect 
the PC to the system programming jack (labeled 
ADMIN
). This is the lower 
modular RS-232 jack on the processor module. (The upper jack is reserved 
for the SMDR printer.)
Local Modem Connection. For a local modem connection, you must use 
a modem (either connected to or built into the PC) to access the internal 
modem in the control unit. Connect the modem to a 012 or 016 (Release 
4.0 and later systems only) module in the control unit.
Remote Modem Connection (DOS-Based SPM Only). For a remote 
modem connection, you must use a modem (either connected to or built 
into the PC) to access the internal modem in the control unit. You must also 
use a modem to dial into the system using remote access.
NOTE:
Remote access (modem connection) has priority over local access (direct 
connection), unless a backup or restore procedure is in progress through a 
direct local connection. If a modem connection is attempted while any other 
type of on-site programming is in progress (either at the system console or 
at a directly connected PC), the system sends a message to the on-site 
programmer. The message indicates that a modem connection is being 
established, and the on-site programming session is terminated.
Access to System Programming
6
Before you can begin system programming from a PC, you need to access the 
SPM software. The procedure for reaching SPM depends on whether your PC is 
connected to the control unit with a modem (either local or remote) or without a 
modem (direct). This section describes both of these procedures.
With a Direct Local Connection
6
To begin using SPM when your PC is connected directly to the control unit, follow 
the steps below. For information about the procedure format, se
Console/Display Instructions
Additional Information
 
Set up the proper physical connections between the PC and control unit.
See Chapter 2 of 
System Programming.
 
If you installed SPM on the hard disk of the PC, go to Step 
.