June 1997
Prior Releases: Features and Enhancements 
Page xxv
Release 4.0 Enhancements 
Voice Announce on Queued Call Console (QCC)
0
The system manager can enable the fifth Call button on a QCC console 
(Hybrid/PBX mode only) to announce a call on another user’s speakerphone 
(providing the destination telephone has a voice announce-capable SA button 
available). A QCC cannot receive voice-announced calls; they are received as 
ringing calls. The factory-set status for the fifth Call button is Voice Announce 
disabled.
Time-Based Option for 
Overflow on Calling Group
0
Release 4.0 has added a 
time
 limit for calls in queue in addition to the previous 
number of calls 
limit. If the Overflow Threshold Time option is set to a valid 
number between 1 and 900 seconds, calls that remain in the calling group queue 
for the set time are sent to the overflow receiver. If the overflow threshold time is 
set to 0, overflow by time is turned off. The factory-set time limit is 0 seconds (off).
Single-Line Telephone Enhancements
0
The following changes enhance the performance of single-line telephones:
Disable Transfer. Through centralized telephone programming, the 
system manager can disable transfer by removing all but one SA or ICOM 
button from the extension.
No Transfer Return. When a handset bounces in its cradle, the system 
interprets this as a switchhook flash and attempts to transfer a call. When 
the transfer attempt period expires, the user’s telephone rings. Release 4.0 
eliminates this unintended ringing by disconnecting the call in situations 
where a switchhook flash is followed by an on-hook state and a dial tone is 
present.
Forward Disconnect. All ports on 012 and 016 modules now send forward 
disconnect to all devices connected to them when forward disconnect is 
received from the CO. This enhancement prevents the trunk/line from 
being kept active when one end disconnects from the call. If an answering 
machine is connected to the port, it does not record silence, busy tones, or 
other useless messages. This operation is not programmable.
Seven-Digit Password for SPM
0
Release 4.0 has increased system security by requiring a 7-digit password for 
system managers or technicians who use SPM to perform programming or the 
Trunk Test procedure. This password is for use in addition to a remote access 
barrier code.