Lucent Technologies 5 User Manual

Page of 429
MERLIN LEGEND Communications System Release 5.0
System Manager’s Guide  
555-650-118  
Issue 1
June 1997
About the System 
Page 2-21
Components 
2
Line/Trunk and Extension Modules
2
The line/trunk and extension modules inserted into the control unit have jacks for 
connecting CO trunks and system telephone wires to the control unit.
A system with a basic carrier has five slots for modules. Up to two expansion 
carriers can be added, each one providing six slots for modules.
The system supports 17 different types of modules that vary in the types of 
lines/trunks that they support and the types of telephones or other equipment that 
can be connected to them.
The names of the modules identify their capacities and capabilities. The first digit 
tells you the number of line/trunk jacks a module supports, while the last two digits 
describe the number of extension jacks it supports. Following the number may be 
letters that indicate the type of trunk it supports, that is, 
LS
 for 
loop-start
 and 
GS
 
for 
ground-start
; if the number indicates line/trunk support and no letters follow, 
the module supports loop-start trunks. For example, the 408 GS/LS MLX module 
provides four line/trunk jacks and eight MLX extension jacks, and supports 
ground-start and loop-start trunks (see 
Figure 2–8. 
408 GS/LS-MLX Module
408
GS/LS-MLX
408 GS/LS
4 GS or LS Outside Lines/ 8 Analog 
Telephones 
(A
TL)
PFT Jack
Digital (MLX)
Extension
Jacks
Line/Trunk 
Jacks