Toshiba 4511 User Manual

Page of 552
November 2003  ©  TOSHIBA TEC
6 - 1
e-STUDIO3511/4511  FIRMWARE UPDATING
6.  FIRMWARE UPDATING
In this equipment, following firmware is written on the ROM on each board.
Firmware
Master data (HDD program data, UI data)
System ROM (System firmware, OS data, UI data)
Engine ROM (Machine firmware)
Scanner ROM (Scanner firmware)
NIC ROM (NIC firmware)
RADF ROM (RADF firmware)
Finisher ROM (Finisher firmware)
Finisher ROM (Saddle stitcher firmware)
FAX ROM (FAX firmware)
Stored
Hard disk
System control PC board (SYS board)
Logic PC board (LGC board)
Scanning section control PC board (SLG board)
NIC board
RADF control PC board (MR-3015)
Finisher control PC board (MJ-1023/ MJ-1024)
Finisher control PC board (MJ-1024)
FAX board (GD-1150)
When you want to update the firmware above or the equipment becomes inoperative status due to
some defectives of the firmware, updating the firmware is available by the following actions.
• Updating with the download jig
6.1 Firmware Updating with Download Jig
• Updating with PC connected
6.2 Firmware Updating with FSMS (Field Service Manager)
• Updating with the USB Storage Device
6.3 Firmware Updating with USB Storage Device
Notes:
• Written firmware varies depending on the kinds of the boards provided as service parts. For updating,
only the minimum firmware is installed on the system control PC board, logic PC board, and scanning
section control PC board. No firmware is installed on the NIC board and FAX board. The latest version
of the firmware at the delivery is written on the RADF control PC board and finisher control PC board.
When any of above boards is replaced with a new one in the field, confirm the other firmware version
used with and then write the suitable version of the firmware.
• The firmware (master data) is not installed on the hard disk provided as a service part. When the hard
disk is replaced with a new one, confirm the other firmware version used with and then write the suitable
version of the firmware.