Campbell Hausfeld HM7500 User Manual

Page of 24
  Gauge of Cord 
 
16 
14 
10
 
 
     Extension cords for 120V/10 Amp Unit
  Length of Cord (ft) 
 
25 
50 
100
HM7500
3
Assembly
FOOT ASSEMbLY (FIGURE 1)
Foot assembly kit includes:
-  3 rubber feet
-  3 bolts
-  6 washers
-  3 nuts
Installation
LOCATION
It is extremely important to install the 
compressor in a clean, well ventilated area 
where the surrounding air temperature 
will not be more than 100°F.
A minimum clearance of 18 inches between 
the compressor and a wall is required 
because objects could obstruct air flow.
 
Do not locate the 
  compressor air inlet 
near steam, paint spray, sandblast areas 
or any other source of contamination. This 
debris will damage the motor.
Household use only. Store indoors.
ELECTRICAL INSTALLATION
1.  Check and tighten all bolts, fittings, 
etc., before operating compressor.
2.  Operate compressor in a ventilated 
area so that compressor may be 
properly cooled.
3.  Compressor should be located where 
it can be directly plugged into an 
outlet, but if this is not possible, an 
extension cord may be used. It should 
be selected using the extension cord 
chart on page 3 as a guide.
4.  To avoid loss of power and 
overheating, it is better to use 
additional air hose instead of 
extension cords to reach work area.
WIRING
1.  Local electrical wiring codes 
differ from area to area. Source 
wiring, plug and protector must 
be rated for at least the amperage 
and voltage indicated on motor 
nameplate, and meet all electrical 
codes for this minimum .
2.  Use a slow blow fuse type T or a 
circuit breaker.
 
 overheating, short  
   circuiting and fire 
damage will result from inadequate 
wiring, etc.
 
All wiring and  
  electrical 
connections should be performed by a 
qualified electrician. installation must 
be in accordance with local codes and 
national electrical codes.
NOTE: 120 volt, compressor can be 
operated on a 120 volt, 15 amp circuit 
under the following conditions:
a. No other electrical appliances or 
lights are connected to the same 
branch circuit.
b. Voltage supply is normal.
c. Extension cords are of the 
minimum gauge specified in this 
instruction manual.
d. Circuit is equipped with a 15 amp 
circuit breaker or a 15 amp slow 
blow fuse type T.
3.  If above conditions cannot be met 
or if nuisance tripping of current 
protection device occurs, it may be 
necessary to operate compressor 
from a 120 volt, 20 amp circuit.
GROUNDING INSTRUCTIONS
1.  This product should be grounded. 
In the event of an electrical short 
circuit, grounding reduces risk of 
electrical shock by providing an 
escape wire for electric current. This 
product is equipped with a cord 
having a grounding wire with an 
appropriate grounding plug. Plug 
must be plugged into an outlet that 
is properly installed and grounded 
in accordance with all local codes 
and ordinances.
 
 improper use of  
   grounding plug can 
result in a possible risk of electrical shock!
 NOTE: Do not use grounding adapter.
2.  If repair or replacement of cord or 
plug is necessary, do not connect 
grounding wire to either flat blade 
terminal. The wire with insulation 
having an outlet surface that is green 
with or without yellow stripes is the 
grounding wire.
3.  Check with a qualified electrician or 
serviceman if grounding instructions 
are not completely understood, or 
if in doubt as to whether product is 
properly grounded. Do not modify 
plug provided; if it will not fit outlet, 
have proper outlet installed by a 
qualified electrician.
 
 Never connect  
   green (or green and 
yellow) wire to a live terminal.
ExTENSION CORDS
 
To avoid loss of  
  power and 
overheating, it is better to use 
additional air hose instead of extension 
cords to reach work area. 
1.  Use only a 3-wire extension cord 
that has a 3-blade grounding plug, 
and a 3-slot receptacle that will 
accept plug on product.
2.  Make sure extension cord is in good 
condition, and heavy enough to 
carry current product will draw. An 
undersized cord will cause a drop in 
line voltage resulting in loss of power 
and overheating.
3.  Table below shows correct size to 
use depending on cord length and 
  Power cord 
White 
Line 
No
  Motor cord 
White 
Load 
No
  Power cord 
Black 
Line 
Yes
  Motor cord 
Black 
Load 
Yes
✽ 
Wire and Terminal Guide
  Wire 
Color 
Terminal 
Hot
(✽) When the unit is not in operation
TEST
RESET
Figure 2 - Grounding Method
Grounding 
Pin
Grounded 
Outlet
www.chpower.com
Rubber Foot
Washer
Bolt
Washer
Nut
Figure 1 - Rubber foot installation